Section 12. System Operation
12–5
Various Security System Trouble Displays
Alpha Display
Fixed Disp. Meaning
ALARM CANCELED
CA
will appear if an exit or interior zone contained a fault during closing at the time
the Exit Delay ended (e.g., exit door left open), but the system was disarmed
during the Entry Delay time. The alarm sounder and keypad sound continuously,
but stop when the system is disarmed. No message will be transmitted to the
central station.
EXIT ALARM
EA
will appear when the Exit Delay ends if an exit or interior zone contained a fault
during closing. The alarm sounder and keypad sound continuously until the
system is disarmed (or timeout occurs). An “Exit Alarm” message is sent to the
central station. Also results if an alarm from an exit or interior zone occurs within
2 minutes after the end of an Exit Delay.
CHECK
CHECK
indicates that a problem exists with the displayed zone(s) and requires attention.
ALARM 1xx
1xx
indicates that communication between control and wireless
FAULT 1xx
1xx
receiver is interrupted, where “xx” is the device address. Check the
CHECK 1xx
1xx
DIP switch settings on the units.
91
If there are wireless sensors in the system, the Check condition may also be
caused by some change in the environment that prevents the receiver from
receiving signals from a particular sensor.
SYSTEM LO BAT
BAT
with no zone number indicates that the system's main standby battery is weak.
LO BAT
BAT
with a zone number and a once-per-minute beeping at the keypad indicates that a
low-battery condition exists in the wireless sensor displayed (zone “00” indicates a
wireless keypad). If the battery is not replaced within 30 days, a “CHECK” display
may occur.
NOTE: Some wireless sensors contain a non-replaceable long-life battery which
requires replacement of the entire unit at the end of battery life (e.g., Nos. 5802,
5802CP).
TELCO FAULT
94
Telephone Line Failure, indicates that a monitored telephone line (if programmed
in field *92) has been cut or disconnected. Depending on how the system was
programmed, the keypad may also produce a trouble sound, and the external
sounder may be activated. Silence by entering installer code + OFF.
Busy-Standby dl
If this remains displayed for more than 1 minute, the system is disabled.
Modem Comm
CC
The system is in communication with the central station for change of function or
status verification.
no display
no display
Power Failure
If there is no keypad display at all and the LEDs are unlit, operating power (AC
and battery) for the system has stopped and the system is inoperative.
If the message “AC LOSS” (Alpha display keypads) or “NO AC” (Fixed-Word
display keypads) is displayed, the keypad is operating on battery power only.
If the battery standby capacity is used up during a prolonged AC power outage,
the control's power will shut down to minimize deep discharge of the battery.
Comm. Failure
FC
A communication failure has occurred.
Open Circuit
OC
The keypad is not receiving signals from the control and sees an open circuit.
Long Rng Trbl
bF
LRR communication failure.
RCVR Jam
90
RF jam detected.
KEYPAD LOW BAT 00 BAT
Wireless keypad low battery
Phone Okay
Cd
The dialer test has been successful (CID code 601).
Dialer Off
dO
The dialer is disabled.
Test in Progress
dd
Walk test mode is active (CID code 607).
Upload Completed
dC
The upload or download session was completed.
Upload Failed
dF
The upload or download session failed before completion.
www.PDF-Zoo.com
firealarmresources.com
Summary of Contents for ADEMCO LYNX XL Series
Page 8: ...LXL 1010 Installation and Setup Guide 1 4 www PDF Zoo com firealarmresources com ...
Page 18: ...LXL 1010 Installation and Setup Guide 2 10 www PDF Zoo com firealarmresources com ...
Page 44: ...LXL 1010 Installation and Setup Guide 6 2 www PDF Zoo com firealarmresources com ...
Page 50: ...LXL 1010 Installation and Setup Guide 8 2 www PDF Zoo com firealarmresources com ...
Page 60: ...LXL 1010 Installation and Setup Guide 11 4 www PDF Zoo com firealarmresources com ...
Page 66: ...LXL 1010 Installation and Setup Guide 12 6 www PDF Zoo com firealarmresources com ...
Page 70: ...LXL 1010 Installation and Setup Guide 13 4 www PDF Zoo com firealarmresources com ...
Page 74: ...LXL 1010 Installation and Setup Guide 14 4 www PDF Zoo com firealarmresources com ...