LYNXR-ISIA Installation and Setup Guide
- 6 -
Wiring Connections
Wiring Overview
The following summarizes the connections required. Refer to the Wiring Connections paragraph and the
Summary of Connections diagram on the inside back cover when making connections.
U
U
U
ULLLL
External sounders have not been evaluated by UL.
07000-005-V1
7845i-L COMMUNICATIONS PORT
(INTERNAL MODULE ONLY)
ALARMNET LRR/IP
COMMUNICATION PORT
LOCAL SOUNDER
DISABLE JUMPER
TERMINAL
STRIP
TELEPHONE
CONNECTIONS
STANDARD AND HIGH CAPACITY
BATTERY CONNECTOR
SUPER HIGH CAPACITY
BATTERY CONNECTOR
INCOMING
PHONE
LINE
TO
HANDSET
PHONE
LINE
WARNING:
TO PREVENT
RISK OF SHOCK
DISCONNECT
TELEPHONE LINE
AT TELECOM
JACK BEFORE
SERVICING
THIS UNIT.
WEEKLY TESTING IS
REQUIRED TO ENSURE
PROPER OPERATION
OF THIS SYSTEM
ALL OUTPUT CIRCUITS ARE POWER LIMITED.
PREMISES
TELEPHONE
1
2
3
4
8
6
5
11
7
10
12
15
16
13
14
PHONE
FUTURE
USE
FUTURE
USE
SOUNDERS
PLCD
AC
EARTH
GROUND
EARTH
GROUND
INCOMING
TELEPHONE
LINE
RING
TIP
RING
TIP
( )
( )
(+)
(+)
( )
PIEZO
6-14VDC
120mA max.
(e.g. WAVE2EX)
6-14VDC
30mA max.
DATA
OUT
SYNC
IN
PO
WERLINE
CARRIER DEVICES
RJ11
8
POS
JACK
AC
AC
SYNC
COM
DATA
9
BELL
09003-009-V0
NOTE
USE ONLY THE K10145X10
TRANSFORMERS PROVIDED
K10145X10
PLUG-IN
TRANSFORMER
9VAC, 25VA
X10
ONLY
CONNECTIONS
GND
D
ATA
I
N
GND
D
ATA
O
U
T
LOCAL SOUNDER DISABLE
SHUNT REMOVE TO DISABLE
STANDARD/HIGH
CAPACITY BATTERY
CONNECTOR
SUPER HIGH CAPACITY
BATTERY CONNECTOR
ALARMNET LRR/IP
COMMUNICATIONS PORT
INTERNAL 7845i-L*
MODULE ONLY
THE LYNXR-ISIA CONTROL IS COMPATIBLE WITH
THE FOLLOWING INTEGRAL RECHARGEABLE
BATTERY PACKS:
REPLACE EVERY FOUR YEARS
P/N LYNXRCHKIT-SC
P/N LYNXRCHKIT-HC
P/N LYNXRCHKIT-SHA
* WHEN AVAILBLE
UL NOTE
THE MINIMUM WIRE SIZE USED FOR TELEPHONE
INSTALLATIONS MUST BE #26 GAUGE
LYNXR-ISIA Wiring Connections