LYNXR-ISIA Installation and Setup Guide
- 61 -
System Communication
Report
3+1/4+1 Standard
3+1/4+1 Expanded
4+2
Alarm
SSS(S) A
SSS(S) A
AAA(A) Z
SSSS AZ
Trouble
SSS(S) T
SSS(S) T
TTT(T) t
SSSS Tt
Bypass
SSS(S) B
SSS(S) B
BBB(B) b
SSSS Bb
AC Loss
SSS(S) E
SSS(S) E
EEE(E) AC
SSSS EAC
Low Battery
SSS(S) L
SSS(S) L
LLL(L) LB
SSSS LLB
Open
SSS(S) O
SSS(S) O
OOO(O) U
SSSS OU
Close
SSS(S) C
SSS(S) C
CCC® U
SSSS CU
Test
SSS(S) G
SSS(S) G
GGG(G)g
SSSS Gg
Restore Alarm
SSS(S) R
SSS(S) R
RRR® Z
SSSS RZ
AC Restore
SSS(S) RA SSS(S)
RA
RARARA(RA)Ac
SSSSRA Ac
Low Battery Restore
SSS(S) RL SSS(S)
RL
RLRLRL(RL)LB
SSSS RLLB
Trouble Restore
SSS(S) RT SSS(S)
RT
RTRTRT (RT)t
SSSS RTt
Bypass Restore
SSS(S) RB
SSS(S) RB
RBRBRB (RB)b
SSSS RBb
ADEMCO Contact ID® Reporting
takes the following format: CCCC Q EEE GG ZZZ where:
CCCC = Customer (subscriber) ID
Q
= Event qualifier, where: E = new event, and R = restore
EEE = Event code (3 hex digits) (for a complete list of event codes, refer to the central office receiver manual)
GG =
Always
“00”
ZZZ = Zone/Contact ID® number reporting the alarm, or user number for open/close reports. System status
messages (AC Loss, Walk Test, etc.) contain zeroes in the ZZZ location.
CONTACT ID® EVENT CODES
Code
Definition
110 Fire
Alarm
121 Duress
122
Alarm, 24-hour Silent
123
Alarm, 24-hour Audible
131 Alarm,
Perimeter
132 Alarm,
Interior
134 Alarm,
Entry/Exit
135 Alarm,
Day/Night
146 Silent
Burglary
150
Alarm, 24-Hour Auxiliary
301 AC
Power
302
Low System Battery/Battery Test Fail
344
RF Jam Detected
353
ECP Communication/Supervision failure, case
tamper or low battery
373
Fire Loop Trouble
374
Exit Error Alarm
380
Global Trouble, Trouble Day/Night
Code
Definition
381
RF Supervision Trouble
383
RF Sensor Tamper
(Trouble)
384
RF Sensor Low Battery
401
Disarmed, Armed AWAY (NO DELAY),
Armed AWAY
403
Scheduled Auto Arm
406 Cancel
by
User
407
Remote Arm/Disarm (Downloading)
408
Quick Arm AWAY/NO DELAY
441
Disarmed/Armed STAY/NO DELAY, Quick Arm
STAY/NO DELAY
459 Recent
Close
570 Bypass
602 Periodic
Test
606
AAV to follow
607 System
Test
623
Event Log 80% Full
654 System
Inactivity
Notes:
(1) The following codes are logged in the event log upon occurrence, but are not reported:
305 = System Reset
627 = Keypad Program Mode Entry
(2) LRR/IP Communications Module Low Battery and Low Battery restore reports are sent real time. LRR/IP Communications
Module trouble restore report is sent after two code + off (only if physically restored)