LYNXR-ISIA Installation and Setup Guide
- 66 -
Programming Default Tables
(boldface indicates defaults that differ between tables)
Function
Table 1
Table 2
Table 3
Table 4
*89 Event log 80% full report code
0,0
0,0
0,0
0,0
*90 Event logging
3
15
3
3
*91 Alarm audio verification/remote phone control
2
2
2
2
*92 Swinger shutdown
1
1
1
1
*93 Flexible call back
0
0
0
0
*94 Download phone number
---
---
---
---
*95 Ring detect count for downloading/remote phone control
15
15
15
15
Default Master Code
1,2,3,4
1,2,3,4
1,2,3,4
1,2,3,4
Default Duress Code
--- --- --- ---
By activating *96, Field 43, and 44 will be changed to 15, 15, 15, 15.
✻
56 ZONE ASSIGNMENT/ALARM REPORT CODES FOR TABLE 1
Zone No. Zone Type Alarm Code
Input Type
Loop Number
Zone Descriptor
2
1
1,0
3 (RF)
2
47, 04 (FRONT DOOR)
3
1
1,0
3 (RF)
2
33, 04 (BACK DOOR)
4
3
1,0
3 (RF)
2
80 (WINDOW)
5
10
1,0
3 (RF)
1
56 (MOTION DETECTOR)
26 21 1,0 5
(BR)
3
27 22 1,0 5
(BR)
2
28 20 1,0 5
(BR)
4
29 23 0,0 5
(BR)
1
30 21 1,0 5
(BR)
3
31 22 1,0 5
(BR)
2
32 20 1,0 5
(BR)
4
33 23 0,0 5
(BR)
1
92 --- --- ---
---
99 6 1,0 ---
---
NOTE: Zone 2 to 41 are RF zones; Zone 92 is Duress; Zone 99 is keypad panic
✻
56 ZONE ASSIGNMENT/ALARM REPORT CODES FOR TABLE 2
Zone No. Zone Type Alarm Code
Input Type
Loop Number
Zone Descriptor
2
1
1,0
3 (RF)
2
47, 04 (FRONT DOOR)
3
1
1,0
3 (RF)
2
33, 04 (BACK DOOR)
4
1
1,0
3 (RF)
2
48, 04 (GARAGE DOOR))
5
04
1,0
3 (RF)
1
56 (MOTION DETECTOR)
6
9
1,0
3 (RF)
1
22, 02 (SMOKE DETECTOR)
26 21 1,0 5
(BR)
3
27 22 1,0 5
(BR)
2
28 20 1,0 5
(BR)
4
29 23 0,0 5
(BR)
1
30 21 1,0 5
(BR)
3
31 22 1,0 5
(BR)
2
32 20 1,0 5
(BR)
4
33 23 0,0 5
(BR)
1
92 --- --- ---
---
95 08 1,0 ---
---
96 09 1,0 ---
---
99 07 1,0 ---
---
NOTE: Zone 2 to 41 are RF zones; Zone 92 is Duress; Zones 95, 96 and 99 are keypad panics