Data Field Descriptions
✻
35
Entry Delay 01
00-99 = entry delay time in seconds.
The system will wait the time entered before sounding alarm upon entering
if system is not disarmed. UL installations: must be set for a maximum of
45 seconds
✻
36
Entry Delay 02
00-99 = entry delay time in seconds.
The system will wait the time entered before sounding alarm upon
entering. UL installations: must be set for a maximum of 45 seconds
✻
37
Audible Exit Warning/Quick Exit
Exit Warning
Quick Exit
0 = no exit warning
sound
0 = no quick
exit
1 = provide exit
warning sound
when armed AWAY
1 = allow quick
exit
Exit Warning: Sound consists of slow continuous beeps until last 5 seconds,
when it changes to fast beeps. The warning sound will end at the
termination of exit delay.
Quick Exit: If enabled, user can restart the exit delay time after arming in
STAY mode by entering the user code and pressing the
STAY
key, or by
pressing the
STAY
key if Quick Arm is enabled. This avoids having the
user disarm then re-arm the system after allowing someone to enter or exit
✻
38
Confirmation of Arming Ding
0 = no ding
1 = confirmation ding after arming system
2 = confirmation ding after arming from RF button or
RF keypad only
Confirmation of arming is provided by a 1/2 second external sounder “ding”
that sounds when closing report is sent, or at the end of exit delay.
If Option 2 is selected the external sounder “ding” occurs immediately after
the system receives the RF transmission.
✻
39
Power Up In Previous State
0 = always power up in a disarmed state
1 = assume the system status prior to power-down
When the system powers up armed, an alarm will occur 1 minute after
arming if a zone is faulted, and any bypassed zones will be unbypassed.
Note: If the previous state was armed
AWAY
or
STAY
, the system will not
respond to sensor changes for 1 minute, which allows time for sensors such
as PIRs to stabilize. UL installations: must be 1 (power up in previous
state)
DIALER PROGRAMMING (
✻
40–
✻
50)
Fields
✻
40,
✻
41,
✻
42:
Enter up to the number of digits shown. Enter 0–9, # + 11 for ‘*’; # + 12 for ‘#’; # + 13 for a pause
(2 seconds)
NOTE:
Whenever AAV is used, primary (field
✻
41) and secondary (field
✻
42) phone numbers should be preceded with the call waiting
disable command. Otherwise, there is the possibility of connection of the third party to LYNX during AAV mode.
✻
40
PABX Access Code
Enter up to 6 digits if PABX is needed to access an
outside line.
If fewer than 6 digits need to be entered, exit by pressing [
✻
]. To clear
entries from field, press
✻
40
✻
.
✻
41
Primary Phone No.
Enter up to 20 digits.
If fewer than 20 digits entered, exit by pressing [
✻
]. To clear entries from
field, press
✻
41
✻
.
Note:
Backup reporting (8 attempts are made to the secondary phone
number if no kissoff is received after 8 attempts to the primary
number) is automatic only if there is a secondary phone number
(field
✻
42).
✻
42
Secondary Phone No.
Enter up to 24 digits.
If fewer than 24 digits entered, exit by pressing [
✻
]. To clear entries from
field, press
✻
42
✻
. See backup reporting note for field
✻
41. If using the
paging feature, enter the pager phone number here.
!
All four digits of the Subscriber Account number must be entered in Fields
✻
43 and
✻
44. If ten digit format is
selected in
✻
48 (option 5), all ten digits of the Subscriber Account number must be entered.
Fields
✻
43 and
✻
44:
Enter [
✻
] as the fourth digit if a 3-digit account number (for 3+1 dialer reporting format) is used. Enter 0 as the first
digit of a 4-digit account number for Nos. 0000–0999. Enter [
✻
] as the fifth digit if a 4-digit account number (for 3+1,
CID®) is used. Exit field by pressing [
✻
] if only 3 digits are used. To clear entries from field, press
✻
43
✻
or
✻
44
✻
. See
blank Programming Form for examples of account number entries. If using the paging feature, do not enter a leading 0
in the subscriber account number, and do not use digits A-F anywhere in the number. Some paging systems provide
voice mail capability, which is activated by a leading 0 in the message. Enter digits 0–9; # +11=B; # +12=C; # +13=D; #
+14=E; or # +15=F.
✻
43
Primary Subs Account No.
Enter a four or ten digit account number.
Enter the primary subscriber account number.
To clear entries from field, press
✻
43
✻
.
✻
44
Secondary Subs Account No.
Enter a four or ten digit account number.
Enter the secondary subscriber account number.
To clear entries from field, press
✻
44
✻
.