VISTA-10P-SOC-V2
CLASS 2 PLUG-IN
TRANSFORMER
16.5V
A
C
, 25V
A
(e
.g.
ADEMCO No
. 1321).
(USE No
. 1321CN IN CANAD
A)
T
O
110V
A
C
UNSWITCHED
OUTLET (24HR)
+
THIS EQ
UIPMENT SHOULD BE INST
ALLED
IN A
CCORD
ANCE
WITH
THE NA
TIONAL
FIRE PR
O
TECTION ASSOCIA
T
ION'S
ST
AND
ARD 72, CHAPTER 2 (NA
T
IONAL
FIRE PR
O
TECTION ASSOCIA
T
ION,
BA
TTER
Y
-MARCH P
ARK, Q
U
INCY
,MA
02269).
PRINTED INFORMA
TION
DESCRIBING P
R
OPER INST
ALLA
T
ION,
OPERA
TION,
TESTING, MAINTENANCE,
E
V
A
C
U
A
T
IO
N
PLANNING AND REP
AIR
S
E
R
V
IC
E
I
S
T
O
BE
PR
O
V
IDED
WITH
THIS
EQ
UIPMENT
.
24-HR B
A
TTER
Y ST
ANDBY REQ
UIRED FOR
FIRE INST
ALLA
TIONS.
USE 12V
, 17.2AH
B
A
TTER
Y FOR 600mA A
UX PO
WER.
SEE
INSTR
UCTIONS.
B
A
TTER
Y CAP
A
C
ITY FOR EMERGENCY
B
URGLAR
Y ST
ANDBY USE A
T
LEAST 4 HRS
USE UL LISTED LIMITED ENERGY
CABLE FOR ALL CONNECTIONS
FOR COMPLETE
INFORMA
TION, SEE
INSTR
UCTIONS K0735
ALARM OUTPUT
10.5
–
13.8VDC
, 2A MAX.
(600mA MAX.
FOR UL
USA
GE, INCLUDING
A
UX PO
WER) STEAD
Y
FOR B
URGLAR
Y/P
ANIC
,
TEMPORAL PULSE
SOUNDING FOR FIRE.
CAN USE ADEMCO No
. 702
SIREN, OR 12V BELL).
SEE INSTR
UCTIONS
.
CHARGING V
O
LT
A
G
E
13.8VDC
. MAXIMUM
CHARGING CURRENT
650mA.
B
A
TTER
Y
12V
, 4AH
+
+
BLA
CK
RED
SEALED LEAD-A
CID
TYPE.
BA
TTER
Y NORMALL
Y NEED NO
T BE
REPLA
CED FOR A
T
LEAST 3
YRS
.
T
O
DETERMINE
T
O
T
AL ST
ANDBY LO
AD
ON BA
TTER
Y
, ADD 100mA
T
O
T
O
T
AL OF
A
UX.
PO
WER OUTPUT AND REMO
TE
KEYP
AD CURRENTS
.
FL
YING LEADS
FOR BA
TTER
Y
CONNECTION
CONNECTION OF
THE FIRE ALARM
SIGNAL
T
O
A FIRE ALARM
HEADQ
U
A
R
TERS OR A CENTRAL ST
A
T
ION
SHALL BE PERMITTED ONL
Y
WITH
THE
PERMISSION OF
THE LOCAL A
UTHORITY
HA
VING JURISDICTION.
THE B
URGLAR
ALARM SIGNAL SHALL NO
T BE
CONNECTED
T
O
A POLICE EMERGENCY
NUMBER.
OPTIONAL
FOR UP TO
16 ADDITIONAL RF ZONES
( AND/OR UP T
O 4 RELA
YS)
ADEMCO 5881*
T
ype
RF RECEIVER
WIRELESS ZONES
ADEMCO No.
4204 RELA
Y MODULE
(4 OUTPUT RELA
YS)
SET UNIT
’S DIP SWITCH FOR DEVICE
ADDRESS 12
SEE INSTR
UCTIONS
.
BLK
RED
GRN
YEL
1
2
3
7
8
11
12
17
20
21
22
23
24
25
EAR
TH
GR
OUND
SEE
INSTR
UCTIONS
FOR PR
OPER
GR
OUNDING
(VIA RJ31X* J
A
CK AND DIRECT
CONNECT CORD)
*CA38A IN CANAD
A
DOC LO
AD NO
.:
3
RED: KEYP
AD PWR (
+
)
GREEN: D
A TA
IN FROM KEYP
AD
YELLOW:
KEYP AD D
A TA
OUT
▲
▲
REMO
TE
KEYP
ADS
AND O
THER
ADDRESSABLE
DEVICES
(e
.g.
5800TM,
4285/4286,
LRR,
4204,
5881)
W
ARNING:
T
O
PREVENT RISK OF SHOCK,
DISCONNECT
TELEPHONE LINE A
T
TELCO
J
A
CK BEFORE SER
VICING
THIS UNIT
.
BLK
RED
GRN
YEL
T
O
TERM
4
T
O
TERM
5
T
O
TERM
6
T
O
TERM
7
BLK
RED
GRN
YEL
AND/OR
RING
(GRA
Y)
TIP
(GREEN)
RING
(RED)
INCOMING
PHONE LINE
HANDSET
TELEPHONE WIRING
ZONE 1
ZONE 2
HI
LO
HI
LO
ZONE 3
ZONE 4
HI
LO
HI
LO
ZONE 5
ZONE 6
HI
LO
HI
LO
MAXIMUM LOOP RESIST
ANCE:
(EA
CH ZONE) 300 OHMS (PLUS EOLR)
•
•
RESPONSE,
ZONES 1-6:
10, 350, OR 700 MSEC (PR
OGRAMMABLE)
5-PIN CONNECT
OR
FOR ON-BO
ARD
TRIGGERS
SEE INSTR
UCTIONS
.
(USE KEYP
AD CABLE)
TIP
(BR
O
WN)
}
THIS DEVICE COMPLIES
WITH P
A
R
T
15 OF FCC R
ULES
.
OPERA
TION IS SUBJECT
T
O
THE FOLLO
WING
TW
O
CONDITIONS:
(1)
THIS DEVICE MA
Y NO
T CA
USE HARMFUL
INTERFERENCE, AND (2)
THIS DEVICE MUST A
CCEPT ANY
INTERFERENCE RECEIVED
, INCLUDING INTERFERENCE
THA
T
MA
Y CA
USE UNDESIRED OPERA
TION.
COMPLIES
WITH FCC R
ULES
, P
A
R
T
68.
FCC REGISTRA
TION NO
. 5GB
USA-44003-AL-E
RINGER EQ
UIV
A
LENCE:
0.1B
.
WEEKL
Y
TESTING IS REQ
UIRED
T
O
ENSURE PR
OPER OPERA
TION OF
THIS
SYSTEM.
IN ADDITION,
THIS SYSTEM MUST BE CHECKED BY A Q
U
ALIFIED
TECHNICIAN A
T
LEAST ONCE EVER
Y
THREE (3)
YEARS.
RED JUMPER
CUT FOR BELL SUPER
VISION.
ALSO
, CONNECT 2000 OHM
RESIST
OR DIRECTL
Y A
C
R
OSS
SOUNDER.
FOR CONNECTION OF OPTIONAL 4285 OR 4286
VIP
MODULES
T
O
PHONE
TERMINALS
, SEE INSTR
UCTIONS
.
5881L:
UP
T
O
8
5881M:
UP
T
O
16
NO
TE:
KEYP
AD (S)
CURRENT AND
ALL O
THER
DEVICES
DRA
WING
PO
WER FR
OM
TERMS 4 & 5
MUST BE
INCLUDED IN
A
UX CURRENT
DRAIN
CALCULA
TIONS
.
2000
OHMS
EOLR
2000
OHMS
EOLR
2000
OHMS
EOLR
2000
OHMS
EOLR
2000
OHMS
EOLR
2000
OHMS
EOLR
GND
+12 AU
X
18
19
16
15
14
13
10
9
6
12
3
4
5
OUTPUT 18
(TRIG. 2)
OUTPUT 17
(TRIG. 1)
ALL DEVICES AND A
CCESSORIES
USED IN A CANADIAN INST
ALLA
TION
MUST BE LISTED FOR USE IN CANAD
A
B
A
TTER
Y FUSE
FOR REPLA
CEMENT
,
USE SAME
V
ALUE
(e
.g.
ADEMCO No
. 90-12)
3A
SET
RECEIVER
’S
DIP SWITCH
FOR DEVICE
ADDRESS
OF
“0
”.
SEE
INSTR
UCTIONS
.
REMO
TE KEYP
ADS
CAN USE 6150 OR 6160
KEYP
ADS
. LOCAL
PR
OGRAMMING
MUST BE DONE
WITH A
6160, B
U
T NEED NO
T
REMAIN IN
THE SYSTEM
(SET
T
O
ADDRESS 16).
PO
WER SHUTDO
WN NO
TE:
SYSTEM SHUTS DO
WN SENSOR
DETECTION PR
OCESSING IF
CONTR
OL'S V
O
LT
A
GE
DR
OPS
BELO
W 9.6V
.
ADEMCO VISTA-10P / VISTA-10PSIA
SUMMARY OF CONNECTIONS
*5882 IN CANAD
A
NO
T USED
NOT USED
BLACK:
KEYP AD GR
OUND (- ) RETURN
A
UX.
PO
WER
OUTPUT
10.5-13.8VDC
600mA MAX.
(500mA MAX.
FOR UL
INST
ALLA
TIONS)
ALL OUTPUTS
ARE PO
WER
LIMITED
.
+
}
BLK
5
4
4-WIRE SMOKE DETECT
OR CONNECTIONS
+
+
2000
OHMS
EOLR
HEAT
DETECTOR
RED
EOL
POWER
SUPERVISION
RELAY MODULE
A77-716B.
USE N.O.
CONTACT,
WHICH CLOSES
WHEN POWER
IS APPLIED.
VIOLET
AUX PWR
OUTPUT
TERMINALS
5
4
_
_
+
BLK
_
TO ZONE TERM. ( )
TO ZONE TERM. ( )
RELAY
CONTACT OPENS MOMENTARILY
UPON FIRE ALARM RESET
PROGRAM RELAY
AS ZONE TYPE 54
(FIRE ZONE RESET)
_
+
4-WIRE SMOKE
OR COMBUSTION
DETECTOR
N.C
.
N.O
.
TO OUTPUT 17
PROGRAM OUTPUT 17 FOR
"OUT NORM LOW" = YES IN
79 MENU MODE AND AS ZONE
TYPE 54 IN 80 MENU MODE
MAX. CURRENT = 100 mA
(UP TO 16 DETECTORS
PLUS EOL MODULE)
OR
Figure 17. Summary of Connections
Summary of Contents for ADEMCO VISTA-10P
Page 36: ...Installation Instructions 4 12 ...
Page 52: ...Installation Instructions 5 16 ...
Page 64: ...Installation Instructions 8 4 ...