ADEMCO VISTA-12A / VISTA-12E
SUMMARY OF CONNECTIONS
V12A_V12E-SOC-V0
+
B
A
TTER
Y CAP
A
C
ITY
FOR EMERGENCY
B
URGLAR
Y ST
ANDBY
USE A
T
LEAST 4 HRS
FOR COMPLETE
INFORMA
TION,
SEE INSTR
UCTIONS
K10022-1
ALARM OUTPUT
10.5
–
13.8VDC
, 2A MAX.
STEAD
YFOR
B
URGLAR
Y/P
ANIC
,
TEMPORAL PULSE
SOUNDING FOR FIRE.
(CAN USE
ADEMCO No
. 702
SIREN, OR 12V BELL).
SEE INSTR
UCTIONS
.
CHARGING V
O
LT
A
G
E
13.8VDC
. MAXIMUM
CHARGING CURRENT
650mA.
B
A
TTER
Y
12V
, 6AH
+
+
BLA
CK
RED
SEALED LEAD-A
CID
TYPE.
BA
TTER
Y NORMALL
Y NEED NO
T BE
REPLA
CED FOR A
T
LEAST 3
YRS
.
T
O
DETERMINE
T
O
T
AL ST
ANDBY LO
AD
ON BA
TTER
Y
, ADD 100mA
T
O
T
O
T
AL OF
A
UX.
PO
WER OUTPUT AND REMO
TE
KEYP
AD CURRENTS
.
FL
YING LEADS
FOR BA
TTER
Y
CONNECTION
OPTIONAL FOR UP TO
16
ADDITIONAL ZONES
( FROM EITHER OR BO
TH GROUPS)
ADEMCO 5800 Series
RF RECEIVER
WIRELESS ZONES
ADEMCO No.
6164
WITH 4 ZONES PLUS 1 RELA
Y
-OR-
ADEMCO No.
4219
WIRED EXP
ANSION MODULE
(8 ADD'L EOLR
WIRED ZONES)
-OR-
ADEMCO No.
4229
WIRED EXP
ANSION/RELA
Y MODULE
(8 ADD'L EOLR
WIRED ZONES PLUS 2
OUTPUT RELA
YS)
-OR-
ADEMCO No.
4204 RELA
Y MODULE
(4 OUTPUT RELA
YS)
1
3
78
11
12
17
EAR
TH GR
OUND
WIRE
(GREEN w/
YELLO
W STRIPE)
SEE INSTR
UCTIONS
FOR PR
OPER GR
OUNDING
BLACK:
KEYP AD
GROUND (- ) RETURN
RED: KEYP
AD PWR (
+
)
GREEN: D
A TA
IN FROM KEYP
AD
YELLOW:
KEYP AD D
A TA
OUT
▲
▲
W
ARNING:
T
O
PREVENT RISK OF SHOCK,
DISCONNECT
TELEPHONE LINE A
T
TELECOM
J
A
CK BEFORE SER
VICING
THIS UNIT
.
BLK
RED
GRN
YEL
T
O
TERM
4
T
O
TERM
5
T
O
TERM
6
T
O
TERM
7
AND/OR
+
ZONE 2
HI
LO
ZONE 3
ZONE 4
HI
LO
HI
LO
ZONE 5
ZONE 6
HI
LO
HI
LO
MAXIMUM LOOP RESIST
ANCE:
(EA
C
H ZONE) 300 OHMS (PLUS EOLR)
•
•
RESPONSE,
ZONES 1-6:
10, 400, OR 700 MSEC
, OR 1.2 SECONDS (PR
OGRAMMABLE)
TRIGGER MODULE
USED FOR X10
CONNECTIONS
,
ON-BO
ARD
TRIGGERS
,
AND A
UX PO
WER
SUPER
VISION,
SEE INSTR
UCTIONS
.
78
(USE SA4120XM-1 CABLE)
RED JUMPER
CUT FOR SIREN SUPER
VISION.
ALSO
, CONNECT 2000 OHM RESIST
OR DIRECTL
Y
A
C
R
OSS SOUNDER.
DO NO
T CUT FOR SELF-A
CTIV
A
TED SIREN OUTPUT
.
NO
TE:
KEYP
AD (S)
CURRENT (IN
ALL P
A
R
T
ITIONS)
AND ALL O
T
HER
DEVICES DRA
W
ING
PO
WER FR
OM
TERMS 4 & 5
MUST BE
INCLUDED IN
A
UX CURRENT
DRAIN
CALCULA
T
IONS
.
}
2000
OHMS
EOLR
2000
OHMS
EOLR
2000
OHMS
EOLR
2000
OHMS
EOLR
2000
OHMS
EOLR
SYNC BLK)
COM (VIO)
D
A
TA
(BLU)
T
O
X-10
TRANS
.
16
15
14
13
10
9
6
5
4
12
3
4
5
6
SET RECEIVER
’S
DIP SWITCH FOR
DEVICE ADDRESS
OF
“0
”.
SEE
INSTR
UCTIONS
.
SET UNIT
’S
DIP SWITCH
FOR DEVICE
ADDRESSES
7 - 15
SEE
INSTR
UCTIONS
.
ZONE
P
A
IRS
1 / 9
2 / 10
3 / 11
4 / 12
5 / 13
6 / 14
TYPICAL WIRING
FOR
ZONE DOUBLING
TYPICAL WIRING
FOR
DOUBLE B
ALANCED ZONE
REMO
TE KEYP
A
DS
CAN USE 6128RF
,
6148, 6150, 6160V
,
OR 6164 KEYP
ADS
.
(FIRST KEYP
AD MUST
BE SET
T
O
ADDRESS 16).
13
12
14
10
11
6.2k
ZONE 10
3k
ZONE 2
2k
2k
2k
ZONE 3
2k
2k
2k
ZONE 4
T
AMPER
CONT
A
CTS
T
AMPER
CONT
A
CTS
PO
WER SHUTDO
WN NO
TE:
SYSTEM SHUTS DO
WN SENSOR
DETECTION PR
OCESSING IF
CONTR
OL'S V
O
LT
A
GE
DR
OPS
BELO
W 9.6V
.
4-WIRE SMOKE DETECT
OR CONNECTIONS
+
+
2000
OHMS
EOLR
HEAT
DETECTOR
RED
EOL
POWER
SUPERVISION
RELAY MODULE
A77-716B.
USE N.O.
CONTACT,
WHICH CLOSES
WHEN POWER
IS APPLIED.
VIOLET
AUX PWR
OUTPUT
TERMINALS
5
4
_
_
+
BLK
_
TO ZONE TERM. ( )
TO ZONE TERM. ( )
RELAY
CONTACT OPENS MOMENTARILY
UPON FIRE ALARM RESET
PROGRAM
RELAY
AS ZONE
TYPE 54
(FIRE ZONE
RESET)
_
+
4-WIRE SMOKE
OR COMBUSTION
DETECTOR
N.C
.
N.O
.
TO OUTPUT 17
PROGRAM OUTPUT 17
FOR "OUT NORM
LOW" = YES IN 79 MENU
MODE AND AS ZONE
TYPE 54 IN
80 MENU MODE
OR
2
REMO
TE
KEYP
ADS
AND O
THER
ADDRESSABLE
DEVICES
(e
.g.
4204,
4219,
4229,
5800TM,
5881EN,7845i)
MODULAR
TELEPHONE
CONNECTOR
N219
VIST
A-12A
APPR
O
VED A
USTRALIA
PO
WER P
A
CK
(e
.g., XF1 60844CK)
B
A
TTER
Y FUSE
FOR REPLA
CEMENT
,
USE SAME
V
ALUE
(e
.g.
ADEMCO No
. 90-12)
3A
ZONE 1
HI
LO
2000
OHMS
EOLR
NOT USED
PHONE CONNECTION
FOR VIST
A-12A
21
22
23
24
25
EAR
TH
GR
OUND
SEE
INSTR
UCTIONS
FOR PR
OPER
GR
OUNDING
PHONE WIRING
FOR
FOR VIST
A-12E
(VIA RJ31X J
A
CK AND DIRECT
CONNECT CORD)
RING
(GRA
Y)
TIP
(GREEN)
RING
(RED)
INCOMING
PHONE LINE
HANDSET
TIP
(BR
O
WN)
}
}
VIST
A-12E
220 V
A
C
WIRED-IN
TRANSFORMER
16.5V
A
C
, 25V
A
TRIG 1
TRIG 2
( )
VTRIG
( ) A
U
X
GROUND FOR SUPERVISED AUX
POWER DEVICES
TRIGGER MODULE
+
ALL OUTPUTS
ARE PO
WER
LIMITED
.
USE TRIGGER
MODULE A
U
X
PO
WER TERMINALS
FOR SUPER
VISED
A
UX PO
WER
CONNECTION
20
19
+
-
+
(OUTPUT 17)
+
12V FOR TRIGGER DEVICE
+
12V FOR SUPERVISED AUX
POWER DEVICES
(OUTPUT 18)
TRIGGER VOLTAGE/AUX POWER
SUPERVISION, CONNECT TO
ZONE TERMINAL ( )
SUPV
( ) GND
NO
TE:
TRIGGERS 1 AND 2 COMBINED
SHOULD NO
T EXCEED 300 mA.
A
UX.
PO
WER
OUTPUT
10.5-13.8VDC
700mA MAX
INCLUDING
TRIGGERS
1 AND 2