Programming Overview
3-9
Data Field Programming Procedures (cont’d)
Task Procedure
Entering Data
When the desired field number appears, simply enter the digits
required. The keypad beeps three times after the last digit is entered
and automatically displays the next data field in sequence.
If entering less than the maximum digits available (e.g., phone
number field), enter the desired digits, then press [
∗
] to end the
entry.
Review a Data Field
Press [#] + [Field Number].
That field’s data is displayed, but no changes can be made.
Deleting an Entry
Press [
∗
] + [Field No.] + [
∗
] (applies only to phone number, account
number, and pager character fields).
Interactive Mode Programming (
∗∗∗∗
56,
∗∗∗∗
57,
∗∗∗∗
58,
∗∗∗∗
79,
∗∗∗∗
80,
∗∗∗∗
81,
∗∗∗∗
82,
∗∗∗∗
83)
Entering Interactive Mode
Press [
∗
] + [Interactive Mode No.] (for example,
∗
56) while in
Program Mode. The Alpha display keypad will display the first of a
series of prompts requesting entries.
After making the appropriate entry, press the [
∗
] key to accept the
entry and continue to the next prompt.
Loading Factory Defaults/Initializing for Download
To Load Default Entries
Data Field, System, and Zone Defaults:
The VISTA-12A and VISTA-
12E each have two unique sets of default entries. The complete default
tables are listed in the
Programming Guide
.
Press
∗
97 while in Program Mode, then press 1 or 2 to load the desired
set of factory defaults (default set 1 or default set 2). This resets all data
fields to the respective default set values shown in the
Programming
Guide
.
User Code Defaults:
To reset only the user codes to default values,
press
∗
97, then press 3.
To Initialize Download ID
Press
∗
96 while in Program Mode. This initializes the system for
downloading and resets all the subscriber account numbers and CSID.
Do not press
✱
97 to load defaults if any programming has been done previously—data
already programmed into the system will be changed!
Exiting the Programming Mode
Prevent installer code reentry
Press
∗
98. Exits Programming Mode and prevents re-entry by:
Installer Code + [8] + [0] + [0]. To enter the programming mode if
∗
98 was used to exit, you must first power the system down. Then
power up again, and press [
∗
] and [#] at the same time, within 50
seconds of powering up.
Allow installer code reentry
Press
∗
99. Exits Programming Mode and allows re-entry by:
Installer Code + [ 8] + [0] + [0] or by: Pressing [
∗
] and [#] at the same
time, within 50 seconds of power-up.
Summary of Contents for ADEMCO VISTA-12A
Page 2: ...ii ...
Page 26: ...Installation and Setup Guide 2 20 ...
Page 82: ...Installation and Setup Guide 5 26 ...
Page 98: ...Installation and Setup Guide 7 4 ...
Page 104: ...Installation and Setup Guide 8 6 ...
Page 108: ...Installation and Setup Guide 9 4 ...