Data Field Programming
4-7
FIELD
TITLE and DATA ENTRIES
EXPLANATION
*55
Dynamic Signaling Priority
0 = Primary dialer first;
1 = ECP Contact ID output first.
Intended for use with Alternative Communication
Media reporting.
You must also enable field
∗
29, ECP Contact ID
Output for ACM.
Select the initial reporting destination for messages
as follows:
Primary Dialer First selected (0):
•
If acknowledged before delay expires (see
∗
54),
then message will not be sent to ECP output.
•
If not acknowledged before delay expires, then
message is sent to both the Primary Phone No.
and ECP output.
ECP Contact ID Output First selected (1):
•
If acknowledged before delay expires, then
message will not be sent to the primary dialer.
•
If not acknowledged before delay expires, then
message is sent to both the Primary Phone No.
and ECP Contact ID output.
System Status Report Codes
Zone report codes are programmed using interactive
✱
56 or
✱
58 Zone Programming modes, while
system status (non-alarm) codes and restore codes are entered in the following data fields. The actual
report code digits that you enter depend upon the particular installation, and should agree with the
Central Station office receiving the signals.
To disable a report code,
enter “0” in the first entry.
3+1, 4+1 Standard or Robofon 8 Format:
Enter a code in the first entry: 1–9, A, B, C, D, E, or F.
Enter #+10 for A (this reports a “0” on some receivers), #+11 for B, #+12 for C, #+13 for D, #+14 for E,
#+15 for F.
Entering 0 in the second box advances to the next field.
Expanded or 4+2 Format:
Enter codes in both entries (first and second digits) for 1–9 or A–F, as
described above. An entry of “0” in the second entry eliminates the expanded message for that report.
ADEMCO or Robofon Contact ID® Reporting:
Enter a digit in the first entry to enable the zone to
report. Use a different digit for each zone until you have used up available digits. If the number of zones
exceeds the number of available digits, begin with digit 1 again. This is an “enabling” code only and is
not the actual code sent to the Central Station office. Entries in the second entry pair are ignored. An
entry of 0 in the first box disables the report.