background image

Quick Start Guide 

Vista-20P 

 

NOTE: DO NOT 

hook power to the keypad until the entire system is installed and 

ready for programming. 

Reason: 

You have to make a programming change to 

each keypad upon 30 seconds of power being sent to the keypad. 

 

Installer Code 

= 4112 

Master Code

=1234 

Program Mode

= 4112+800 

Or 

Upon 50 seconds of power up, you will need to press and hold * and # at 

same time. 

 

Exit Programming

=*99 or 00 depending on where you are at 

 

*=Change Data 

#=View Data 

 

Step 1: Assign Keypad Address 

  Within 30 seconds of the main keypad receiving power: 

Press and hold 

the 1 and 3 buttons 

at the same time.  

 

Con Addr = 

will appear and you will need to enter 16. Then press * 

  On each additional keypad you will need to enter a unique address: 17, 

18, etc.  

o

 

Do Not Duplicate Keypad Addresses.

 Keypads have to be 

addressed 16 to 23 (no duplicates), but come defaulted at 31 and 
will not work until they are re-addressed.  

 

Step 2: Enter Programming 

After the keypad is addressed, you will need to 

enter programming: 

 

 

Enter 4112 800 

 

  Field 20 (Installer Code) will be displayed on the screen. 

 

We can begin programming from this point. 

 

Step 3: Default the Entire System (*97)

 

  Enter *97 to default your system. The system will beep. This will ensure 

that there is a clean slate to start from. 

  If you will be using central station monitoring:  

Press *96 

and the system 

will beep. This is for clearing the ID number for Central Station. 

 

Step 4: Installer Code (*20)

 

  If you would like to change the installer code, press *20 + new installer 

code. 

Be sure not to forget this number.

 

 

 

Summary of Contents for Ademco VISTA-20P

Page 1: ...n each additional keypad you will need to enter a unique address 17 18 etc o Do Not Duplicate Keypad Addresses Keypads have to be addressed 16 to 23 no duplicates but come defaulted at 31 and will not work until they are re addressed Step 2 Enter Programming After the keypad is addressed you will need to enter programming Enter 4112 800 Field 20 Installer Code will be displayed on the screen We ca...

Page 2: ... for both partition 1 and 2 even if only 1 partition will be used 30 to 90 seconds enter the desired seconds 30 90 97 120 seconds 98 180 seconds 99 240 seconds Note You will not need to enter 35 if you have just completed step 5 Enter the entry delay time for Entry Delay 1 on Partition 1 Then enter the entry delay time for Entry Delay 1 on Partition 2 Then enter the entry delay time for Entry Dela...

Page 3: ...e Types 00 Not Used 04 Interior follower 08 24 Hr Aux 21 Arm Away 01 Entry Exit 1 05 Trouble Day Alarm Night 09 Fire no delay 22 Disarm 02 Entry Exit 2 06 24 Hr Silent 10 Interior delay 23 No Alarm Response 03 Perimeter 07 24 Hr Audible 20 Arm Stay 24 Silent Burglary Enter the Zone Number you wish to program and press A summary screen will be displayed Press again to advance past the summary scree...

Page 4: ...umber you wish to program and press A summary screen will be displayed Press again to advance past the summary screen Enter the Zone Type ZT Refer above or go to page 5 2 in the Installation and Setup Guide for the exact types Press to continue Enter the partition number PT 1 or 2 NOTE Partition 3 is for common areas between partitions 1 and 2 Then press Report Code RC should be left at 01 The sum...

Page 5: ...o your system Keep in mind keypads can be addressed 16 to 23 with no duplicates in the addresses The keypad should come defaulted at 31 but we will default the keypad to make sure everything is correct Step 1 Upon Power Up of the new keypad when the main display goes blank Press and hold the 1 and 3 simultaneously Then oo will flash Step 2 While oo is flashing enter 91 then the system will beep an...

Page 6: ...isplay shows Function Key chosen for next for previous menu Step 3 Choose Function for this Key for next for previous menu 00 A Zone 95 B Zone 99 C Zone 96 D Single Button Page 01 Single Button Page sends 999 9999 message to Pager 02 Display Time 03 Arm Away 04 Arm Stay 05 Arm Night Stay any Zone in User List 3 06 Step Arming Stay then Night Stay then Away 07 Device A Activation Type 66 Function i...

Reviews: