*191
Keypad 3 Device Address 18
See field *190 for entries and explanation.
*192
Keypad 4 Device Address 19
See field *190 for entries and explanation.
*193
Keypad 5 Device Address 20
See field *190 for entries and explanation.
*194
Keypad 6 Device Address 21
See field *190 for entries and explanation.
*195
Keypad 7 Device Address 22
See field *190 for entries and explanation.
*196
Keypad 8 Device Address 23
See field *190 for entries and explanation.
*197
Exit Time Display Interval
0 = no display; 1-5 = seconds between display updates
If enabled, keypads display the exit time remaining after
arming the system, updated at the interval selected (i.e.
if the exit delay is 30 seconds and “2” is selected in this
field, the keypad display refreshes every 2 seconds,
displaying 30, 28, 26, 24, etc.).
An interval greater than “1” may be necessary for some
older keypads to allow users time to enter key presses
between display updates.
TOUCH SCREEN DEVICE NOTE:
If using more than
one touch screen device (e.g., 6270, Symphony) with the
system, leave field *197 Exit Time Display Interval set to
the default value “0.” The 6270 automatically displays
remaining exit time in one-second increments.
FIXED-WORD KEYPAD NOTE:
If using 2-digit
display keypads (e.g. 6150RF), do not use exit times
greater than the 96-second delay option. Using a longer
delay time may cause end-user confusion because 2-digit
display keypads cannot display times greater than “99.”
If longer exit time is required by the installation, it is
recommended that the Exit Time Display option be
disabled (“0”).
*198
Display Partition Number
0 = no; 1 = yes
If selected, the partition number is displayed in the
upper-left corner of the display. This is useful when
using the GOTO partition function.
*199
ECP Fail Display
0 = 3-digit display (
“
1
”
+ device address)
1 = 2-digit fixed-display as
“
91
”
Select “0” if using Alpha keypads and/or 3-digit Fixed-
Word Display keypads. ECP faults will display “1” plus
the device address (00-15) of device causing the fault
(e.g., faults on device 07 display as “107”).
Select “1” if using 2-digit Fixed-Word Display keypads
(e.g., certain 6128 series keypads). If selected, ECP faults
for all devices will display as “91” on 2-digit displays, and
“191” on 3-digit or Alpha keypads.
Installation and Setup Guide
4-12
Summary of Contents for Ademco VISTA-21iPSIA
Page 26: ...Installation and Setup Guide 2 20 ...
Page 78: ...Installation and Setup Guide 6 8 ...
Page 84: ...Installation and Setup Guide 8 4 ...
Page 88: ...Installation and Setup Guide 9 4 ...
Page 89: ...Notes 9 5 ...