C
”
01 Enter Zn No.
12
Zone Number
(prompt appears
if zone number was selected)
Enter the desired zone number associated with this output number.
Press [
✱
] to continue.
Enter the zone event that will activate this output.
01 Enter Event
0 = restore; 1 = alarm/fault/trouble
Restore 0
Press [
✱
] to continue to the “Output Action” prompt
01 Output Action
Close for 2 sec
1
Output Action
0 = off
4 = Change Device State
1 = Close for 2 seconds
5 = Duration 1 (see data field *177)
2 = Stay Closed
6 = Duration 2 (see data field *177)
3 = Pulse on & off (1 sec ON, 1 sec OFF)
Enter the desired device action as listed above. Press the [
✱
] key to continue.
Enter Output No.
R02 02
Output Number
01-16 = output no.; 17-18 = on-board triggers
Enter the device output number (programmed in *79 Menu Mode) you want associated with
this output. Press [
✱
] to continue.
02 A E P TRIG
R02 1 1 3 ZL=00
Summary Screen
A summary screen appears showing the programmed settings.
Press [
✱
] to continue.
About Zone Lists (*81 Menu Mode)
Zone lists let you group individual zones for use with certain system actions. The following table shows the
available zone lists and their purposes:
List No.
Used for…
Notes
1, 2
general purpose (GP)
3 chime-by-zone
(see field *26 to enable option)
4
cross zones (see note at right)
5
night stay zones
6
general purpose
V21iPSIA
: dial delay disable
7 general
purpose
V21iPSIA
: unlimited reports
8 general
purpose
9
zones that activate Pager 1
10
zones that activate Pager 2
11
zones that activate Pager 3
12
zones that activate Pager 4
•
Any list may include any or all of the system's zone
numbers.
•
A zone list can be assigned to more than one output relay.
•
Zone List 4: When creating zone list 4 for cross zoning,
include only zones assigned to zone types 3, 4, or 5. Do not
include zones that have delays (entry/exit zones, interior
w/delay) or 24-hour zones, as these zone types may produce
unpredictable operation and may not function as intended.
See field *85 for Cross Zone Timer option.
•
Zone List 6:
V21iPSIA
:
See field *50 for Dial Delay Disable
option.
•
Zone List 7:
V21iPSIA
:
See field *93 for Unlimited Reports