S E C T I O N 4
Data Field Programming
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
About Data Field Programming
The following pages list this control’s data fields in numerical order. Field numbers are listed in the
left column followed by a “Title and Data Entries” column, which lists the valid entries for each field.
Experienced installers can simply follow this column when programming the data fields. The
“Explanation” column provides explanatory information and special notes where applicable.
Use the blank programming form to record the data for this installation.
Programming Data Fields
Data field programming involves making the appropriate entries for each of the data fields.
Start Data Field programming by entering the installer code + 8 + 0 + 0.
System Setup Fields
FIELD
TITLE and DATA ENTRIES
EXPLANATION
*20
Installer Code
Enter 4 digits, 0-9
The Installer Code is used to assign the 4-digit Master Security Code.
See "Master Code" in the
System Operation
section
for procedure.
*21
Quick Arm Enable
0 = do not allow quick arm
1 = allow quick arm
If enabled, a user code is not needed to arm the system. Instead,
users can press the [#] followed by an arming key to arm the system.
However, the user code is always needed to disarm the system.
*22
RF Options
Entry 1 - Jam detection
0 = no RF Jam detection; 1 = detect RF Jam
Entry 2 – supervision interval
0 = 12 hours; 1 = 2 hours; 2 = 20 minutes
when disarmed/ 2 hours when armed
3 = 12 hrs for burg zones/ 3 hrs for fire zones
If jam detection enabled, a report is sent if the system detects an RF
jamming signal. See field *178 for other jam/supervision options.
When using RF Receivers with 5800 series transmitters, entry 2
should be 0 or 3.
*23
Quick (Forced) Bypass
0 = no quick bypass
1 = allow quick bypass (code + [6] + [#] )
All zones bypassed by this function will be displayed after the bypass
is initiated.
*24
RF House ID Code
00 = disable all wireless keypad usage
01–31 = House ID for partition 1, 2, 3
The House ID identifies receivers and wireless keypads. If a 5827 or
5827BD wireless keypad or 5804BD/5804BDV transmitter is being
used, a House ID code
must
be entered, and the keypad must be set
to the same House ID. You can assign RF house ID for each
partition.
Does not apply to 5839 or 5828/5828V.
*25
Arming Prevention Override
Entry 1: 0 = no arming prevention override
1 = allow system to arm with an RF
supervision failure
2 = allow system to be armed with
an AC Mains Loss
4 = allow system to be armed with a
system low battery
Entry 2: 0 = no tamper override
1
†
= allow system to be armed with
a tamper fault
2
†
= allow system to be armed with
a tamper fault once
If no override is selected, systems will not be able to be armed when
there is either a supervision failure, system low battery, AC mains
loss, or a tamper condition.
If override is enabled, the user must enter the arming sequence twice
to arm the system; the first entry of user code + arm command will
not arm, but a second entry of user code +arm command will arm the
system.
E.g., To select arm with “supervision failure” and “low battery”, enter
5 (1 + 4)
† NOTE:
If tamper option 1 or 2 is selected, field *175 digit 2 must
be “0.”
*26
Chime By Zone List 3
0 = no zone list (chimes on fault of
any
entry/exit or perimeter zone when chime
mode on)
1 = use zone list (chimes on fault of
specific
zones programmed in zone list
3 when Chime mode on)
If enabled, you can define the specific zones intended to chime when
faulted while the system is in Chime mode. Use zone list 3 to assign
these zones (see
∗
81
Zone List Programming
section for details).
4-1
Summary of Contents for ADEMCO VISTA-48A
Page 4: ......
Page 28: ...Installation Instructions 3 8 ...
Page 60: ...Installation Instructions 5 20 ...
Page 75: ... NOTES 8 5 ...