FIELD
TITLE and DATA ENTRIES
EXPLANATION
*47
Phone System Select/Dialer
Attempts
Phone System Select:
If Central Station Receiver
is
not
on satellite
link: 0 = Decadic Pulse Dial; 1 =
Multifrequency Tone Dial
If Central Station Receiver
is
on satellite
link: 2 = Decadic Pulse Dial;
3 = Multifrequency Tone Dial
Dialer Attempts:
1 – 10 (for 10, enter #+10)
Phone System Select:
Select the type of telephone service.
Dialer Attempts:
Enter the number of times the system should
attempt to dial the central station, 1 – 10 times (for 10, enter #+10).
*48
Report Format
(Primary/Secondary)
0 = 3+1, 4+1 ADEMCO L/S STANDARD
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
5 = CID* using 10-digit account number
6 = 4+2 ADEMCO EXPRESS
7 = CID* using 4-digit account number
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
10 = ROBOFON 8 (6-digit account number)
11 = ROBOFON Contact ID
Select report format for primary and secondary phone numbers.
* ADEMCO Contact ID format
Audio Beeps Format (Follow-Me):
To enable the audio “beeps”
format (Follow-Me feature), refer to the System Features section
later in this manual, and the User Guide.
Special Contact ID Report Codes:
The following three reports are
valid only when Contact ID format is enabled: 412-Successful
Download/Access (see field *53), 461-Wrong Code Entry (see field
*188), and 626-Time/Date Inaccurate (see field *53).
*49
Split/Dual Reporting
0 = disable (standard/backup report only).
1 - 5 (see table to right)
To Primary No.
To Secondary No.
1 = alarms, restore, cancel
others
2 = all except open/close, test
open/close, test
3 = alarms, restore, cancel
all
4 = all except open/close, test
all
5 = all
all
*50
Burglary Dialer Delay
0 = no dial delay
1 = 15 seconds
2 = 30 seconds
3 = 45 seconds
Provides delay of “BURGLARY ALARM” report to the central station,
which allows time for the subscriber to avoid a false alarm
transmission. This delay does not apply to zone type 24 alarms (silent
burglary) or to 24-hour zone types 6, 7, and 8 (silent panic, audible
alarm, auxiliary alarm), which are always sent as soon as they occur.
*51
Part. 3 Primary Subs. Acct. No.
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Enter up to 10 digits, depending on the report format selected in field
*48.
*52
Part. 3 Secondary Subs. Acct. No.
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Enter up to 10 digits, depending on the report format selected in field
*48.
*53
SESCOA/Radionics Select/
CID Codes
SESCOA/Radionics:
0 = Radionics (0-9, B-F reporting)
1 = SESCOA (0-9 only reporting)
Contact ID Codes:
0 = disable both Time/Date Inaccurate and
Successful Download/Access reports
1 = enable Time/Date Inaccurate report
(code 626);
2 = enable Successful Download/Access
report (code 412)
3 = enable both Time/Date Inaccurate and
Successful Download/Access
SESCOA/Radionics:
Select SESCOA or Radionics format.
Select 0 for all other formats.
Contact ID (CID) Codes:
If desired, enable the Time/Date
Inaccurate and/or Successful Download/Access report codes. These
reports are valid only when Contact ID reporting format is used.
*54
Dynamic Signaling Delay
0 = disabled (both signals sent)
1–15 = entry times a 15-second delay.
e.g., 1 = 15 seconds, 2 = 30 seconds, etc.
Intended for use with ECP Contact ID Output reporting via ACM.
This field lets you select the time the panel should wait for
acknowledgment from the first reporting destination (see
∗
55) before
it attempts to send a message to the second destination. Delays can
be selected from 0 to 225 seconds, in 15-second increments. This
delay is per message. If ”0” is entered in this field, the control panel
will send redundant reports to both Primary Dialer and ECP output.
Installation Instructions
4-4
Summary of Contents for ADEMCO VISTA-48A
Page 4: ......
Page 28: ...Installation Instructions 3 8 ...
Page 60: ...Installation Instructions 5 20 ...
Page 75: ... NOTES 8 5 ...