Installation Instructions
2-14
Phone Line Connections
Connect incoming phone line and handset wiring to the
main terminal block (via an RJ31X jack) as shown in the
Summary of Connections diagram at the back of this
manual. Wire colors represent the colors of the cable to
the RJ31X jack.
Notes
•
If you are using an Audio Alarm Verification
(AAV) unit, refer to
Audio Alarm Verification
(AAV)
section for special wiring connections.
CAUTION:
To reduce the risk of fire, use only
0.6mm O.D. or larger telecommunication line cord
for phone line connections.
Alternative Communications Media (ACM)
Connections
Connect the data in/data out terminals and voltage input
terminals of the ACM to the control's keypad connection
points.
Set the ACM’s address to “03” following the instructions
provided with the ACM.
Notes
•
Use compatible ACMs (e.g., 7845i, 7845C/7835C
[in Latin America], AI4164RS, AI4164ETH).
Audio Alarm Verification Connections
(AAV, “Listen-In”)
Refer to the connection diagram below.
Connections use one of the on-board triggers.
UL
UL installations using the AAV feature must use the
ADEMCO UVCM module (part of the ADEMCO UVS
system).
Suggested AAV Module:
ADEMCO UVS (shown) or Eagle 1250
Notes
•
Set field *91 for AAV and program the appropriate
output (output 17 or 18) using *80 Menu mode
(select zone type “60”).
•
For voice session monitoring, connect an EOLR
zone to UVCM module terminals 6 & 7, and
program the zone as zone type 81 (*56 Menu
mode).
E.g., Using output 18 for the trigger, program an
output function in *80 Menu mode as:
ZT = 60, P = 0, Action = 1, Device = 18
ON
ON
1
2
345
67
8
1
2
345
67
8
12
3
4
5
6
78
9
1
0
1
1
29
30
31
32
33
34
NOTE:
REFER TO UVCM MODULE
INSTRUCTIONS FOR
CONNECTIONS TO AUDIO
SPEAKERS AND MICROPHONE.
UVCM
MODULE
ZONE
TERMINALS
EARTH
GROUND
RED (R)
GREEN (T)
GREY (R)
BROWN (T)
TRIGGER
CONNECTOR
OUTPUT 18
EOL
RING
TIP
OPTIONAL
MONITORING ZONE
CONNECTION
(USE ZONE TYPE 81)
FALLING VOICE TRIG
GND
+12VDC IN
SWITCH
BANK 2
SWITCH
BANK 1
SWITCH BANK 2
SWITCH BANK 1
AUXILIARY
AUDIO LEVEL
ADJUSTMENT
TRIM POT
aa
v_uvcm-003-V0
CONTROL
INCOMING
PHONE LINE
TO
PREMISES
HANDSET
5
1 = ON
2 = ON
3 = OFF
4 = ON
5 = ON
6 = ON
7 = ON
8 = ON
1 = OFF
2 = OFF
3 = OFF
4 = OFF
5 = OFF
6 = OFF
7 = OFF
8 = ON
23
24
25
+12VDC
GND
4
5
21
22
RJ31X
Figure 14. Connection of AAV Unit