7845GSM/7845GSMCN Installation and Setup Guide
3-14
PROMPTS ZONE
TRIG.
4204/
2-4204
ENTRY OPTIONS
DESCRIPTION
32
Restore Zn2 Y/N
(Y)_
✔
✔
[Y], [N]
Enables restore reporting for zone 2.
33
Delay Zn2 (secs)
(00)_
✔
✔
[01-15]
[00] = no delay
Defines the reporting delay in seconds for zone 2.
34
Rpt Zn2 ONLY if
Armed (N)_
✔
✔
[Y], [N]
Reports alarms on zone 2 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; zone 8 in 2-4204 mode) is
triggered (armed).
If [N], always reports alarms on zone 2.
If Lynx Panic is enabled, then skip to Prompt 39: "Rpt Zn3 ONLY if Armed."
35
Zn3 Trigger Type
(V+)_
✔
•
(EOLR)
•
(V+)
•
(V–)
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
36
Invert Zn3 Y/N
(N)_
✔
[Y], [N]
Inverts the alarm and normal states of the zone
3 trigger; otherwise uses normal input signal.
37
Restore Zn3 Y/N
(Y)_
✔
✔
[Y], [N]
Enables restore reporting for zone 3.
38
Delay Zn3 (secs)
(00)
✔
✔
[01-15]
[00] = no delay
Defines the reporting delay in seconds for zone 3.
39
Rpt Zn3 ONLY if
Armed (N)_
✔
✔
[Y], [N]
Reports alarms on zone 3 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; zone 8 in 2-4204 mode) is
triggered (armed).
If [N], always reports alarms on zone 3.
4204 mode:
If any zone is programmed to
"Report Only if Armed," skip to Prompt 50:
"Enable Zn6."
40
Zn4 Trigger Type
(V+)_
✔
•
(EOLR)
•
(V+)
•
(V–)
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
41
Invert Zn4 Y/N
(N)_
✔
[Y], [N]
Inverts the alarm and normal states of the zone
4 trigger; otherwise uses normal input signal.
42
Restore Zn4 Y/N
(Y)_
✔
✔
[Y], [N]
Enables restore reporting for zone 4.
43
Delay Zn4 (secs)
(00)
✔
✔
[01-15]
[00] = no delay
Defines the reporting delay in seconds for zone 4.
44
Rpt Zn4 ONLY if
Armed (N)_
✔
2-
4204
only
[Y], [N]
Reports alarms on zone 4 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 8 in 2-4204 mode) is triggered (armed).
If [N], always reports alarms on zone 4.
45
Zn5 Trigger Type
(V+)_
✔
•
(EOLR)
•
(V+)
•
(V–)
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
46
Invert Zn5 Y/N
(N)_
✔
[Y], [N]
Inverts the alarm and normal states of the zone
5 trigger; otherwise uses normal input signal.