Internet Communication Module 7845i-GSM Installation and Setup Guide
3-14
PROMPTS ZONE
TRIG.
4204/
2-4204
ENTRY OPTIONS
DESCRIPTION
30
Open/Close Zone
(0)_
✔
✔
Zone Trig: [3-7]
4204: [1-4]
2-4204: [1-8]
[0] = not used
Enter the zone number to be used for open/close
(arm/disarm) reports.
This zone assignment must be unique from the
telco zone selected in Prompt 29.
Zone Trigger Mode:
If any zone is programmed
for "report only if armed," zone 7 cannot be
used as an open/close zone. If Lynx Panic is
enabled, zone 3 cannot be used.
4204 Mode:
If any zone is programmed for
"report only if armed," zone 4 cannot be used
as an open/close zone.
2-4204 Mode:
If any zone is programmed for
"report only if armed," or if tamper is enabled,
zone 8 cannot be used as an open/close zone.
NOTE:
Connect an open/close (arm/disarm)
trigger (or relay output) from the control panel to
the open/close zone.
31
Zn1 Trigger Type
(V+)_
✔
•
(EOLR)
•
(V+)
•
(V–)
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
32
Restore Zn1 Y/N
(Y)_
✔
✔
[Y], [N]
Enables restore reporting for zone 1.
33
Delay Zn1 (secs)
(00)_
✔
✔
[01-15]
[00] = no delay
Defines the reporting delay in seconds for zone 1.
34
Rpt Zn1 ONLY if
Armed (N)_
✔
✔
[Y], [N]
Report alarms on zone 1 ONLY if the conditional
zone (zone 7 in zone trigger mode; zone 4 in 4204
mode; or zone 8 in 2-4204 mode) is triggered
(armed).
If [N], always reports alarms on zone 1.
35
Invert Zn2 Y/N
(N)_
✔
[Y], [N]
Inverts the alarm and normal states of the zone
2 trigger; otherwise uses normal input signal.
36
Restore Zn2 Y/N
(Y)_
✔
✔
[Y], [N]
Enables restore reporting for zone 2.
37
Delay Zn2 (secs)
(00)_
✔
✔
[01-15]
[00] = no delay
Defines the reporting delay in seconds for zone 2.
38
Rpt Zn2 ONLY if
Armed (N)_
✔
✔
[Y], [N]
Reports alarms on zone 2 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; zone 8 in 2-4204 mode) is
triggered (armed).
If [N], always reports alarms on zone 2.