PRODUCT DATA

69-1981-06

AQ255 and AQ257 Series 

Expansion Zoning Panels

PRODUCT DESCRIPTION

The AQ255/AQ257 Series Expansion Zoning Panels provide 

additional zoning capacity for an existing hydronic installation 

controlled by an AQ2000 Series Boiler Control Panel such as 

an AQ250 Relay Boiler Control, an AQ251 Reset Boiler 

Control, or an AQ252 Universal Injection/Mixing Boiler Reset 

Control. 

FEATURES

The AQ255/AQ257 Series Expansion Zoning Panels have the 

following features:

• Availability of 4 Expansion Zoning Panels.
• Zone control of either pumps or zone valves, in 

multiples of 4 zones

• 4-zone or 8-zone models for pump zoning; 4-zone 

models for zone valves

• Ability to use both zone valve models and zone pump 

models in the same installation

• Zone valve panels contain an AQ10X38 transformer 

(power supply module), which connects to 120 Vac 

power and supplies 24 Vac power to the Zoning 

Module.

• Communications between components via the 

AQUATROL® network, using communication bus 

wiring.

• Any panel can be configured to activate a group pump 

when zones are active

• Zone valve models can be used with Normally Open or 

Normally closed valves

• Can be installed up to 500 ft. away from main AQ2000 

Control Panel, for convenient operation of remote 

zoning equipment

                                                                                                                                                                                                            

IMPORTANT

To ensure correct installation and proper operation of 

the zoning panel, perform the 7 installation steps in 

the order numbered in the “Contents”  below.

                                                                                                                                                                                

AQ25742B

AQ25582B

Contents

Specifications ...................................................................

2

1 Installation Preparation ..................................................

2

2 Mounting ........................................................................

4

3 Wiring Procedure ...........................................................

5

4 Configure the Expansion Zoning Panel(s) DIP Switches  5

5 Test and Check Out the Installation ...............................

7

6 Purge Air from all System and Zone Piping  ..................

8

7 Document and Keep a record of all System Settings  ....

9

Troubleshooting ................................................................ 10

Appendix .......................................................................... 11

Wiring Diagrams  ................................................... 11

Summary of Contents for AQ15540B

Page 1: ...ransformer power supply module which connects to 120 Vac power and supplies 24 Vac power to the Zoning Module Communications between components via the AQUATROL network using communication bus wiring Any panel can be configured to activate a group pump when zones are active Zone valve models can be used with Normally Open or Normally closed valves Can be installed up to 500 ft away from main AQ200...

Page 2: ...o 110 C Inputs Outputs R C Input 24 Vac Class II R C Output on transformer AQ25742B and AQ25744B only 38 VA 24 Vac Class II Thermostat Compatibility Digital non communicating thermostats and or AQ1000 Series 2 wire communicating thermostats Dimensions HxWxD 8 0 x 9 4 x 3 3 in 20 3 x 23 8 x 8 5 cm approximate Weight 3 9 lb 1 8 kg Approvals Canadian Standards Association Certified File No LR76030 1 ...

Page 3: ...otally new family of hydronic controls And although they and other AQ2000 system components are very easy to install and operate they are different than other hydronic controls that you have previously installed Take a moment to read through this document before beginning the installation Failure to follow these instructions could damage the product or cause a hazardous condition Familiarize Yours...

Page 4: ...ert them into their slot to from a wiring channel between the Main Control Panel and the Expansion Zoning Panel see Fig 3 and to connect the two panels together 4 Install two top screws of the Expansion Zoning Panel ensuring it is level with the adjoining Main Control Panel and install two lower screws 5 Repeat steps 1 4 for any additional Expansion Zoning Panels Fig 3 Orientation of wire channel ...

Page 5: ...rminals is connected to which of the B B Exp Bus IN terminals 4 Wire the zoning equipment to the output terminals bot tom edge of the Expansion Zoning Panel line voltage circulators or valves for the AQ25542B and AQ25582B and low voltage zone valves for the AQ25742B and AQ25744B 5 Bring power to the Expansion Zoning Panel as follows a AQ25542B run 14 AWG jumper wires from the N and L terminals on ...

Page 6: ...c For the third Zoning Module connected to an AQ2000 Series Control Module make sure that DIP switch 3 is set to the right hand position ON and DIP switches 1 2 and 4 are set to the left d For the fourth Zoning Module connected to an AQ2000 Series Control Module make sure that DIP switch 4 is set to the right hand position ON and DIP switches 1 2 and 3 are set to the left 2 Review the settings for...

Page 7: ...els Auto Test AQ155 AQ157 Zoning Modules Auto Test operation for Zoning Modules enables the installer to test all zones wired to the Zoning Module by sequentially activating the zoning equipment connected to each zone output Each step of the Auto Test routine may be paused or skipped by pressing the Test button Table 2 AQ15540B Zoning Module Pump Zoning Module DIP Switch Arrangement DIP Switch Swi...

Page 8: ... with a delay of 1 10th of a second delay between each pump to minimize the effect of inrush currents from the pumps motors along with the main boiler pump When zone valves are tested simultaneously the valves are energized immediately but the boiler pump is energized only after either a the valves end switches close or b the TIME TO OPEN value in the EQUIPMENT SETUP ZONING menu has elapsed to all...

Page 9: ... and saved in the Installing Contractor s files SAVE Feature AQ25A AQ251 and AQ252 Control Panels In addition to the hardcopy Installation Job Records the AQ25A AQ251 and AQ251 Control Panels have a convenient SAVE feature that allows the installing contractor to save the specific equipment setting for this installation in the Control Panel s memory for future recall in case the system s settings ...

Page 10: ...mostats without zone synchronization or waiting for permission from the Control Module to operate This allows the zones to extract any heat provided by the boiler When communication is lost between a Zoning Module and any of its thermostats that zone is invisible to the Control Module The Zoning Module stops serving that zone and the zone s pump or valve de energizes Under this condition the AQ200...

Page 11: ...981 06 APPENDIX This appendix provides examples for wiring Expansion Zoning Panels to AQ2000 Series Control Panels and wiring additional low voltage VA capacity Wiring Diagrams Fig 5 Wiring of AQ25542B Expansion Zoning Panel to AQ2000 Series Control Panel ...

Page 12: ...AQ10X38 TRANSFORMER FROM B B EXP BUS OUT CONNECTION ON AQ1554P2 1 FROM C ON AQ10X38 TRANSFORMER THERMOSTATS ZONE 1 ZONE 2 ZONE 3 ZONE 4 TH SENSOR TH SENSOR THERMOSTATS ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 1 ZONE 2 ZONE 3 ZONE 4 M27833C ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 1 ZONE 2 ZONE 3 ZONE 4 AQ15540B 1 AQ15540B 2 AQ15540B 3 TO N ON AQ10X38 POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION A...

Page 13: ...or recommended wiring of additional low voltage VA capacity to AQ2000 Series Zoning Modules CAUTION Equipment Damage Hazard Can damage internal circuitry of Zoning Module The ES1 and ES2 terminals of the AQ15740B Zoning Module are powered terminals and must only be connected to a set of dry contacts such as a zone valve motor s end switch If power is applied to these contacts for example by runnin...

Page 14: ...ZONE 4 M27835C M M M M M M M M FROM B B EXP BUS OUT CONNECTION ONAQ15540B 1 AQ15540B 1 AQ15540B 2 AQ10X38 120 V AC 1 POWER SUPPL Y PROVIDE DISCONNECT MEANSAND OVERLOAD PROTECTIONAS REQUIRED 1 N L AQ25742B ZONING MODULE OFAN EXISTING AQ2000 SERIES CONTROL P ANEL OK AQ15100B THERMOSTATS ZONE 1 ZONE 2 ZONE 3 ZONE 4 TH SENSOR M27836C M M M M Zone 1 Zone 2 Zone 3 Zone 4 FROM B B EXP BUS OUT CONNECTION ...

Page 15: ...AQ255 AND AQ257 SERIES EXPANSION ZONING PANELS 15 69 1981 06 ...

Page 16: ...NELS Automation and Control Solutions Honeywell International Inc 1985 Douglas Drive North Golden Valley MN 55422 customer honeywell com U S Registered Trademark 2013 Honeywell International Inc 69 1981 06 M S Rev 08 13 Printed in United States ...

Reviews: