Boiler is 

cold, 

house is 

cold 

Display is ON; 

TT-LED is ON

B1 LED is ON

120 Vac at B1-

B2

If no, replace control.

If yes, check burner 

and wiring

Display is ON; 

TT-LED is ON

Refer to 

err

 on 

display

Boiler is 

hot, house 

is cold

Display is ON; 

TT-LED is ON

C1 LED is ON

120 Vac at C1-

C2

120 Vac at C1-C2, 

check wiring to pump

Wiring ok, is pump 

running? If not, 

replace the pump.

If pump is running, 

check for trapped air 

or closed zone 

valves.

Display is ON; 

TT-LED is ON 

C1 LED is OFF; 
ZC LED is ON

b

Boiler below the 

Low Limit 

temperature, 

wait for boiler to 

go above Low 

Limit 

temperature.

Display is ON; 

TT-LED is ON 

ZC LED is 
OFF

c

Boiler above 

LL

? If yes, 

check for 120 

Vac between ZC 

and L2

If no 120 Vac, 

replace control.

If yes, check zone 

relays, circulators 

and wiring.

Table 3. Troubleshooting Guide

a

.

System 

Condition

Diagnostic 

Condition

Check

Action

a

. Refer to Fig. 5 for Display and LED locations.

b

. ZC LED ON indicates ZC terminal power is OFF.

c

. ZC LED OFF indicates ZC terminal power is ON.

69-1957-1.fm  Page 4  Tuesday, June 20, 2006  11:06 AM

Summary of Contents for AQUASTATIC L7224 Series

Page 1: ... High Limit LL Low Limit Ldf Low Limit differential F C F or C Then press the UP and or DOWN buttons to move the set point to the desired value After 60 seconds without any button inputs the control will automatically return to the READ mode To use the L7224U in a cold start boiler application disable the Low Limit function by pressing the UP arrow button DOWN arrow button and I buttons simultaneo...

Page 2: ...nviraCOM wiring Err3 Hardware fault replace control Err4 B1 fault check B1 wiring voltage Err5 Low Line Check L1 L2 110 Vac Err6 Fuse Check ECOM wires Replace fuse Err7 EEPROM HL LL Hdf Ldf Reset to default values Err8 Repeated B1 fault voltage present at B1 when output is turned off check B1 wiring voltage Boiler Temperature Text Description Display Shows bt High Limit HL Low Limit LL High Limit ...

Page 3: ...unction and restarts when error is corrected During the error check sequence the system checks for drift in the sensor and corrosion in the connections Error conditions 6 7 If error condition 6 or 7 occurs the control has reset the High Limit Low Limit and Differential Setting to a default setting and will continue to run at those settings Performance of the system will be degraded Error condition...

Page 4: ...at C1 C2 120 Vac at C1 C2 check wiring to pump Wiring ok is pump running If not replace the pump If pump is running check for trapped air or closed zone valves Display is ON TT LED is ON C1 LED is OFF ZC LED is ONb Boiler below the Low Limit temperature wait for boiler to go above Low Limit temperature Display is ON TT LED is ON ZC LED is OFFc Boiler above LL If yes check for 120 Vac between ZC an...

Reviews: