CONVERSION WIRING DIAGRAMS
FOR
BC7000L1000
The diagrams and instructions contained in this booklet are for converting the following model
programmers to BC7000 Microcomputer Based Burner Control System.
TABLE OF CONTENTS
Page
Section l . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...2
Fireye C, D, and E-Series
Section II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...6
Fireye P-Series
Section III . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Honeywell R4126, R4127, R4181
Section lV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Honeywell R4140, R4150 with 20 Terminal Subbase (120 V only)
Section V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...29
Honeywell R4150 with 13 or 15 Terminal Subbase
1. Installer must be a trained, experienced, flame safeguard control service technician.
2. Disconnect power supply before beginning installation to prevent electrical shock and
equipment damage.
3. All wiring must comply with applicable local electrical codes, ordinances, and regulations.
4. Voltage and frequency of the power supply and flame detector(s) connected to this control
must agree with those marked on the device.
5. Loads connected to the control terminals must not exceed those listed in the SPECIFI-
CATIONS section.
6. All external timers must be listed or component recognized by authorities having
jurisdiction, for the specific purpose for which they are used.
7. Perform all required checkout tests after installation is complete.
IMPORTANT
For on-off, gas-fired systems, some authorities having jurisdiction prohibit the wiring of any
limit or operating contacts in series with the main fuel valve(s).
P.G.
Rev. 6/89
Form Number 66-6002—4
©Honeywell Inc. 1989
Summary of Contents for BC7000L1000
Page 3: ...E1214A FIREYE 70D10 26CF6 5022 26 CU6 5065 EP160 EP161 EP170 TO BC7000L PM720L2004 or 1030 ...
Page 5: ...E1216E FIREYE 24CJ5 5015 70D20 26CF6 5023 25 CU65055 EP260 EP261 EP270 TO BC7000L PM720G2005 ...
Page 7: ...E1221A FIREYE 26RJ8 1016 1016T 26RJ8 1012 1012T 6012 6012T TO BC7000L PM720G2005 ...
Page 8: ...E1693 FIREYE 25RLJ84580 TO BC700L PM720L1030 ...
Page 9: ...E1217B FIREYE 25RU8 6560 6570 6580 26RJ8 6060 6070 6080 6160 TO BC7000L PM720L1030 ...
Page 10: ...E1218A FIREYE 29RF5 1001 1009 6009 TO BC7000L PM720G2013 ...
Page 11: ...E1219A 26RJ8 6058 6066 6068 25RU8 6558 6566 TO BC7000L PM720G2005 ...
Page 14: ...E1222A R4126A1172 1180 1198 TO BC7000L PM720L2004 ...
Page 16: ...E1224A R4126A1073 1164 TO BC7000L PM720L2004 ...
Page 17: ...E1753 R4127A1155 AND R4127A1197 TO BC7000L PM720G2005 ...
Page 19: ...E1724A R4127A1171 R4127B1039 R4127B1047 TO BC7000L PM720G2005 ...
Page 20: ...E1226A R4181A1000 R4181A1026 TO BC7000L PM720G2005 ...
Page 21: ...E1227A R4181A1018 R4181A1034 TO BC7000L PM720L2004 ...
Page 22: ...E1228A R4181A1042 R4181A1059 TO BC7000L PM720L2004 ...
Page 30: ...E1229A CONVERSION FOR R4150A B AND C MODELS 120 VOLT ONLY USE BC7000L PM720M2002 ...
Page 32: ...E1231A CONVERSION FOR R4150G1012 AND G1079 MODELS 120 VOLT ONLY USE BC7000L PM720M2002 ...
Page 33: ...E1232A CONVERSION FOR R4150M USE BC7000L PM720M2002 ...