79
GasAlertMicro 5/PID/IR
View Datalog Files in Spreadsheets
Table 18. Datalog Status Codes
Note: TWA readings greater than 99 are recorded as OL.
Status Codes
Normal operation
G
Backlight is on
L
Low alarm
v
STEL and high alarm (dual alarms)
1
Alarm setpoint 1 (low alarm)
H
High alarm
w
TWA and STEL alarm (dual alarms)
2
Alarm setpoint 2 (high alarm)
T
TWA alarm
x
TWA, STEL, and low (triple alarms)
3
Alarm setpoint 3 (TWA alarm)
U
TWA and low alarm (dual alarms)
y
TWA, STEL, and high (triple alarms)
4
Alarm setpoint 4 (STEL alarm)
V
TWA and high alarm (dual alarms)
O
Overload / sensor is over-ranged
D
Calibration due date (days)
s
STEL alarm
C
Calibrating
E
Elapsed / last calibration (days)
u
STEL and low alarm (dual alarms)
F
Failure - sensor failure
Z
Auto zeroing
f
Fresh air delay
I
Time set
t
Testing
@
Zero CO
2
Pump Codes
P
Plugged (blocked) - pump alarm
F
Failure / pump failure
Battery Status Codes
Batteries OK
B
Low battery alarm
C
Confidence beep is active
Alarm Status Codes
L
Low alarm
M
Multi alarm
S
Automatic shutdown
H
High alarm
C
Calibration
F
Failure / self-test fail
T
TWA alarm
Q
Off / quit / manual deactivation
R
RTCC / real-time clock failure