Page 30
1 Dec 2003
34-45-4
7
MAINTENANCE MANUAL
CAS-100 COLLISION AVOIDANCE SYSTEM
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
Table 10. IVA-81A TA/VSI Leading Particulars
Characteristic
Description
Form Factor
3ATI x 7.5 inches deep
Components
Solid state, no mechanical parts
Maximum Weight
2.75 lb (1.25 kg)
Overall Dimensions
See Outline Drawing, Figure
2011.
Mounting
Front, panel mount
Power Requirements
115 V, 400 Hz, 28 Watts (maximum), or 28 V dc primary
power
±12 V dc reference power if altitude rate source input is
ARINC 575 analog
26 V ac reference power if altitude rate source input is
ARINC 565 analog
5 V ac or dc or 28 V dc lighting power
Operating Temperature Range
-15C to +70C
Number of Intruder Aircraft Displayed
Determined by TCAS processor TA/RA display symbols
maximum program strap configuration.
Display
High resolution, full color dot matrix LCD. Combination
vertical speed, RA, and traffic display.
Vertical Speed Input
The IVA-81A meets the requirements of both type B and type
C VSI indicators. Pneumatic or air data electrical input. Both
ARINC 500 and 700 series air data input accepted.
Inputs from TCAS
High-speed ARINC 429
Front-Mounted Range Control
Optional
Front-Mounted TA SEL Switch and BRT
Control
Optional