background image

USE & OPERATION (CONTINUED)

CLEANING & DRAINING THE WATER TANK

CLEANING THE CARBON DUST FILTER* AND HONEYCOMB COOLING MEDIA

3

Move the unit to a location where the water can be drained. Remove the cap from the Drain plug
located at the bottom of the unit. Allow the tank to empty.
Refill the water tank with clean water, up to the maximum level and drain it completely.
Use a damp cloth to remove the dirt and dust from the surface of the unit. Never use corrosive 
elements or chemicals to clean this product.
When the product is not in use, store the unit in a dry place our of direct sunlight.

t

t
t

t

The appliance is supplied with a Carbon Dust Filter* &
Honeycomb Cooling Media.
The Carbon Dust Filter* and Honeycomb Cooling Media are
located inside the Rear Grill. See Figure 1 for instructions on
how to remove them from the unit for cleaning and
maintenance.
Do not run the unit in COOL mode with stale water in the 
tank. You must empty the water tank and refill with fresh 
water, especially if the tank has not been cleaned in a long 
time.
The cleaning frequency for the Honeycomb media depends 
on local air and water conditions. In areas where the mineral
content of water is high, mineral deposits may build up on the
Honeycomb Cooling Media and restrict air flow. Draining the
water tank and refilling with fresh water at least once a week 
will help reduce mineral deposits. If mineral deposits remain 
on the Honeycomb Cooling Media, the media should be 
removed and washed under fresh water. The media should 
be cleaned every two months or sooner, depending on your 
needs.
For best results allow the Honeycomb Cooling Media to dry 
after each use by turning off the cool function 15 minutes 
before turning the unit off.

t

t

t

t

t

FILLING WITH WATER

WARNING:

Before cleaning the unit, switch the unit OFF and disconnect from the electrical socket.

CAUTION:

Unplug the unit from the electrical power outlet before emptying or 
refilling the water tank.

Open the Water Fill Door.

The Water Level Indicator is located at the back of the unit. Refill the 
water tank when water level is low. Do not fill water above the "Max." 
water level mark. To avoid water spillage and water droplets at the 
louvers, do not fill water above the maximum indicator level. Check the 
water level in the tank before running the COOL function. Make sure 
that the water in the tank is above the minimum water level mark. 
Running the unit in COOL mode with inadequate water may cause 
pump failure.

If the cooler will not be used for a long period of time, please refer to the STORAGE & MAINTENANCE 
GUIDELINES located in the separate Safety & Maintenance Guide.

Honeycomb 

Cooling Media

Figure 1:

Remove all the screws from the Rear Grill of the Air 
Cooler.
Carefully pull out the rear grill from the cooler.
Slide out the Carbon Dust Filter* and clean with water.
Slide the Honeycomb Media from the Honeycomb 
Frame.
Replace or clean media with water and a damp cloth as 
needed.

WARNING:

 DO NOT operate the Air Cooler when the 

Rear Grill is removed from the Air Cooler, or if there is a 
loose-fitting Rear Grill. Doing so can cause serious 
injury or dangerous electrical shock.

1.

2.
3.
4.

5.

Removing the Carbon Dust Filter*/ Honeycomb
Cooling Media:

*Applicable for models with Carbon Dust Filter only.

Water Fill Door

Rear Grill

Honeycomb 

Frame

Carbon Dust

Filter

Screws 

Summary of Contents for CL15AE

Page 1: ...www honeywellaircoolers com E mail info honeywellaircoolers com Portable Evaporative Air Cooler Safety Maintenance Guide User tips and safety instructions ...

Page 2: ...el and there must be water in the water tank Doors and windows should be opened to allow free air flow The Evaporative Air Cooler works best when placed near an open window so that outside air is drawn into the Evaporative Air Cooler circulates in the room then exits via the door The maximum cooling effect is felt when a person is near the flow of air coming out of the Evaporative Air Cooler The E...

Page 3: ...ket by grasping and pulling on the plug end of the cord This appliance has been manufactured for use in domestic environments and must not be used for other purposes DO NOT use in areas where gasoline paint or other flammable goods and objects are stored When using the COOL setting make sure the water tank is at Max Indicator Level Operating the unit on the COOL setting with an empty tank may resu...

Page 4: ...u must switch off the water supply and remove the drain tube before draining the water tank This function is only available on some Honeywell Air Cooler models Check the User Manual to see if your unit has the Continuous Water Supply Function Clean the water tank with a damp cloth to wipe away any dust or mineral deposits Remove the Honeycomb Cooling Media and Carbon Dust Filter from the Air Coole...

Page 5: ...all amount of rain on the unit is not a problem as long as the electrical plug and outlet are dry If they are wet DO NOT touch the unit or electrical plug outlet Switch off the master power for the outlet before unplugging the unit from the electrical outlet Make sure all outlets and plugs are dry before use The Air Cooler is designed to IPX4 product standards and not recommended to be placed outd...

Page 6: ...Model CL15AE www jmatek com E mail usinfo jmatek com Portable Evaporative Air Cooler User Manual Read and save these instructions before use ...

Page 7: ...W THESE INSTRUCTIONS MAY DAMAGE AND OR IMPAIR ITS OPERATION AND VOID THE WARRANTY POWER Press the POWER button to turn the unit on The cooler will start automatically at medium speed After a few seconds the speed will switch to low To turn the unit off press the button again SPEED Press the SPEED button repeatedly to change the speed between L M H Sleep The indicator light will show the selected s...

Page 8: ...INUED REMOTE CONTROL FUNCTION BUTTONS CONTINUED 2 LOUVER MOVEMENT COOLER LOCATION Make sure to position the air cooler correctly before you set up and start using the product Please refer to the COOLER LOCATION section of the separate Safety Maintenance Guide Power Speed Mode Swing Timer ON OFF Low Medium High Sleep Evaporative Cooling On Off Controls the motion of the louvers Controls timer funct...

Page 9: ... on your needs For best results allow the Honeycomb Cooling Media to dry after each use by turning off the cool function 15 minutes before turning the unit off t t t t t FILLING WITH WATER WARNING Before cleaning the unit switch the unit OFF and disconnect from the electrical socket CAUTION Unplug the unit from the electrical power outlet before emptying or refilling the water tank Open the Water F...

Page 10: ...om Web www jmatek com Made in China 2015 JMATEK Limited All rights reserved The Honeywell Trademark is used under license from Honeywell International Inc Honeywell International Inc makes no representations or warranties with respect to this product This product is manufactured by JMATEK Limited ...

Reviews: