background image

8

USE & OPERATION (CONTINUED)

EN

CLEANING THE WASHABLE MESH FILTER AND HONEYCOMB COOLING MEDIA

The appliance is supplied with a Washable Mesh Filter and Honeycomb Cooling Media.
The Washable Mesh Filter and Honeycomb Cooling Media are located inside the Rear Grill (See 
Figure 1 and 2) and see below for instructions on how to remove them from the unit for cleaning.
Do not run the unit in COOL mode with stale water in the tank. You must empty the water tank 
and refill with fresh water, especially if the tank has not been cleaned in a long time.
The cleaning frequency for the Honeycomb media depends on local air and water conditions. 
In areas where the mineral content of water is high, mineral deposits may build up on the 
Honeycomb Cooling Media and restrict air flow. Draining the water tank and refilling with fresh 
water at least once a week will help reduce mineral deposits. If mineral deposits remain on
the Honeycomb Cooling Media, the media should be removed and washed under fresh water. The 
media should be cleaned every two months or sooner, depending on your needs.
For best results allow the Honeycomb Cooling Media to dry after each use by turning off the cool 
function 15 minutes before turning the unit off.


• 
 
 
 
 
 

Slide out the Washable Mesh Filter and clean with 
water.
Remove all the screws from the Rear Grill of the Air 
Cooler.
Carefully pull out the rear grill from the cooler.
Carefully pull out the Honeycomb Cooling Media 
from the rear grill.
There are two Horizontal Bars holding the 
Honeycomb Cooling Media in place. Remove all the 
screws from the Horizontal Bars and then pull the 
bars off of the Honeycomb Cooling Media.
Replace or clean media with water and a damp 
cloth as needed.

1. 

2.
 
3. 
4.

5.

6.

Removing the Washable Mesh Filter/ Honeycomb Cooling Media:

WARNING: 

Switch the unit OFF and disconnect from the electrical socket.

WARNING: 

DO NOT operate the Air Cooler when 

the Rear Grill or Honeycomb Media is removed from 
the Air Cooler, or if there is a loose-fitting Rear Grill 
or Honeycomb Cooling Media. Doing so can cause 
serious injury or dangerous electrical shock.

Honeycomb 

Cooling Media

Horizontal Bar

Screws

Screws

Rear Grill 

Washable 

Mesh

Filter

Figure 1:

Figure 2:

Summary of Contents for CL70PE

Page 1: ...Portable Evaporative Air Cooler User Manual Web Read and save these instructions before use Model CL70PE CO70PE ...

Page 2: ... 17 Drain Plug 9 Power Cord Plug PARTS DESCRIPTION EN 4 5 6 7 8 9 3 2 1 15 16 17 10 11 12 13 14 WARNING READ AND SAVE THE AIR COOLER SAFETY MAINTENANCE GUIDE AND USER MANUAL BEFORE USING THIS PRODUCT FAILURE TO FOLLOW THESE INSTRUCTIONS MAY DAMAGE AND OR IMPAIR ITS OPERATION AND VOID THE WARRANTY IN CASE THERE IS ANY INCONSISTENCY OR CONFLICT BETWEEN THE ENGLISH VERSION AND ANY OTHER LANGUAGE VERS...

Page 3: ...rs during heavy rain or snow FOR OUTDOOR MODEL CO70PE WARNING Use only on GFCI Protected outlets sockets for USA only Press the TEST button then RESET button every month to ensure proper operation Power cords must be secured to avoid tripping The wiring and connections must be protected from water The electrical plug and Air Cooler connections must be dry at all times When used outdoors insert the...

Page 4: ...y wet Pressing the button until both S and C are illuminated will activate both Swing Vertical Louvers and Cool modes simultaneously Note When the C mode is not selected the unit functions in a fan only mode without evaporative cooling FUNCTION BUTTONS SPEED Press the button repeatedly to change the speed between High Medium Low The indicator light will show the selected speed TIMER Press the butt...

Page 5: ...E The remote control requires AAA 2 x 1 5V batteries for replacement Open the battery compartment at the back of the remote control and insert the batteries inside Care must be taken to insert the batteries according to the correct polarity markings shown inside the battery compartment Always point the remote control signal transmitter towards the unit when operating Make sure that the signal path...

Page 6: ...o ensure there will be no leaks If there is leakage the hose and the water inlet valve may not be connected properly Try to disconnect replace and tighten the water inlet valve again When the connection is secured turn ON the water supply and the water will flow into the water tank of the cooler The cooler is now set so the water refills automatically When the water tank is full the water inlet va...

Page 7: ...the unit The Water Level Indicator is located at the front of the unit Refill the water tank when water level is low Do not fill water above the Max water level mark to avoid water droplets collecting on the louvers Check the water level in the tank before running the COOL function Make sure that the water in the tank is above the minimum water level mark Running the unit in COOL mode with inadequ...

Page 8: ...loth to remove the dirt and dust from the surface of the unit Never use corrosive elements or chemicals to clean this product When the product is not in use store the unit in a dry place out of direct sunlight If the cooler will not be used for a long period of time please refer to the STORAGE MAINTENANCE GUIDELINES located in the separate Safety Maintenance Guide WARNING Before cleaning the unit ...

Page 9: ...ter The media should be cleaned every two months or sooner depending on your needs For best results allow the Honeycomb Cooling Media to dry after each use by turning off the cool function 15 minutes before turning the unit off Slide out the Washable Mesh Filter and clean with water Remove all the screws from the Rear Grill of the Air Cooler Carefully pull out the rear grill from the cooler Carefu...

Reviews: