Additionally, each pulse channel may also be configured to receive a user-specified FixedFactor
multiplier. By default, this multiplier is disabled but may be activated by inserting the desired factor into
item 044 for Ch1 and item 440 for Ch2. The FixedFactor feature is normally used to adjust the
accumulated uncorrected volume for a fixed pressure factor or fixed temperature factor (or both).
The number of digits for Accumulated Volume and FixedFactor Volume can also be assigned for both
channels. (item numbers 097, refer to
Scaling related Item Numbers
in the Appendix section.)
Ch1 Item#
Ch2 Item#
FixedFactor Volume
000
908
Incremental FixedFactor Volume
225
909
FixedFactor Value
044
440
FixedFactor Volume Units
090
457
FixedFactor Volume Digits
096
096
Table 1-2
: Quick Reference: Items associated with FixedFactor Volume