Ch Item #
Item Name
Description
497
Modem Retry A Count
Default =3
Following a failed Scheduled or Alarm call-in, the
maximum number of Interval A (primary) retry
attempts,
9.1.8 Scaling Factor Item Codes
The “Scaling Factor” is a multiplier, pulse scaling can be applied using their respective Input Pulse
Scaling items (if needed) before the pulses are stored (added) to their respective accumulated totals This
affects how the recorded pulse counts are reported to the host system.
Ch1 versus Ch2 volumes units can be independently scaled.
Items-114 and 913 are used in conjunction with other Item Codes to convert the raw pulse counts to
some other more meaningful value. The value of the Item Code translates to a multiplier “SFm[Item]”,
which is any value between 0.0 and 200.0. Example: If Item-913 is set for a value of 2.3 then SFm [913] =
2.3.
Example: Assume the most recent interval count is 29 pulses and the total count so far is 10332.
Scaling Factor Reported Interval Reading Reported Total
1
29
10332
0.5
14 (see Note-1)
5166
2
58
20664
0.1
2 (see Note-1)
1033 (see Note-1)
2500
??? (see Note-2)
25830000
Table 9-1
: Examples of Using the Scaling Factor
9.1.9 Modem Item Codes
Item
#
Item Name
Item Description
Possible Values
3002
Cloud Link 4G
Modem Serial
Number
Cloud Link 4G Modem Serial Number
19 character string
3003
Cloud Link 4G
Modem
Manufacturing Date
Cloud Link 4G Modem Manufacturing data
19 character string,
DD:MM:YYYY.
3004
Radio IMEI number
Radio identification number
19 character string
3005
Change Battery
Tells Cloud Link we have inserted a new battery.
Resets the "available % battery life" (3011)
calculation and updates Battery type (3007)
0 - Clear, 1 - Set.
3006
Modem Advance
Low Battery
Indication
Advance Low Battery Indication (in days):
Maximum allowed is 180 days and Min allowed is
7
Min = 7Days Max =
180 Days
9 Appendix
Honeywell
| 62