Item
#
Item Name
Item Description
Possible Values
cellular network, if the Maximum Transmission
Unit (MTU) of the network is lower than the
configured packet size, the packet size should be
decreased to be smaller than the MTU. On an LTE
network the MTU is typically 1200 bytes.
3100
Firmware image
max size allowed
32 bit Integer (in
Bytes)
3101
Coordinated
Universal Time
(UTC)
When the Cloud Link 4G Modem receives a time
and date, it is relative to Coordinated Universal
Time (UTC), which is essentially the same thing as
Greenwich Mean Time (GMT).
32 bit Integer Min =
0 Sec Max =
4294967295 Sec
3102
Date format type
0 - MMDDYY, 1 -
DDMMYY, 2 -
YYMMDD.
3103
Cloud Link 4G
Modem Bootloader
version
String
3104
Cloud Link 4G
Modem Bootloader
CRC
32 bit Integer
3105
Modem Call On Low
Battery Enable
Whenever selected, Cloud Link will call the IP
addresses defined in 3037-3040 on Low battery
conditions (requires PowerSpring)
0 - Disable, 1 -
Enable.
3106
Modem Call On
Magnetic Switch
Enable
Whenever selected, Cloud Link will call the IP
addresses defined in 3037-3040 when the switch
magnet is activated (requires PowerSpring)
0 - Disable, 1 -
Enable.
3108
Modem Date
3109
Modem Time
InHH MM SS
3110
Server mode IP
address
Used when CLoudLink is in integrated mode. This
parameter needs to be configured by the user so
that Cloud Link knows its IP address (Call Out
mode)
39 character string
(Min 12
characters)
3111
Server mode IP port
number
Used when CLoudLink is in integrated mode. This
parameter needs to be configured by the user so
that Cloud Link knows which port to listen on (Call
Out mode). This port shall be configured in
MasterLink or PowerSpring for example.
16 bit integer Min =
1024 Max = 65535
3112
BLE connection
interval
Advertisement interval max : data value in mSec
16 bit integer Min =
8 mSec Max = 4000
mSec
3113
Pulse count
Cloud Link 4G Modem has a feature to count the
raw pulses coming from an input switch. This adds
the advantage of getting redundant counts along
with the counts from the actual meter measured by
the external EVC. To use this functionality, you
need to enable and configure this feature (Item
3136). If you want to start from a specific value, to
16 bit integer Min =
1 Max = 99999999
9 Appendix