Item
#
Item Name
Item Description
Possible Values
TAC
Identification ID in 2G or 3G.
3134
Last call duration
Lats successful call duration
Usigned integer 32
bits (in Sec)
3135
Last call status
Last call status
0 - No Call, 1 - Call
in Init, 2 - Dialing,
3 - Dial Failed, 4 -
Connected, 5 -
Failed Due to No
Response, 6- PPP
Failed, 7 - TCP
Conn Failed, 8 -
Low Super Cap, 9 -
Invalid IP
Configuration, 10 -
Success.
3136
Pulse count enable
Enables the Cloud Link 4G Modem pulse Counting
input. See Item 3113.
0 - Disable, 1 -
Enable.
3137
Modem
Restore/Reset/Clear
logs
This item can be used to clear some logs or do a
firmware reset on Cloud Link. Writing to this
parameter is instantaneous and does not require
disconnecting from the instrument. 1 'Restore
Defaults-Device Config' - Similar to a factory
default done by shortening the pins. 7 'Restore
Defaults-Security Config' - Clears the SSL
certificate, issue time, expiry time,... 8 'Restore
Defaults-Battery Config' - Clears battery
configuration : battery type, battery change, ... 9
'Modem Reset' - Firmware reset. 10 'BLE Module
Reset' 11 'Restore Defaults-Internal Config'
0 - None, 1 -
Restore Defaults-
Device Config, 2 -
Clear Event Logs, 3
- Clear Alarm Logs,
4 - Clear
Diagnostic Logs, 5
- Clear Cellular
Logs, 6 - Clear All
Logs, 7 - Restore
Defaults-Security
Config, 8 - Restore
Defaults-Battery
Config, 9 - Modem
Reset, 10 - BLE
Module Reset, 11 -
Restore Defaults-
Internal Config.
3138
Modem server
timeout
Used when connecting to third party EVCs which
do not support Call Out start and end time. This
parameter can be used defines how long Cloud
Link will remain in server mode.
Unsigned Integer
32 bits Min = 60
Sec Max =
4294967295 Sec
3139
Remote Unit ID 2
(RUID)
String, 6 characters
3140
Temperature units
Units used when displaying the modem board
temperature (item 3114).
0 - Degree Celcius,
1 - Farenheit, 2 -
Rankine, 3 - Kelvin.
3141
BLE number of
bonds
Number of devices which have paired with Cloud
Link. See item 3082.
Unsigned Integer 8
bits
3142
MIWireless Enable
0 = for 350 or integrated mode(default), 1 =
MiWireless. In MiWireless mode, the modem will
directly connect to the cellular network when the
power is applied. In EC350 or integrated mode,
once the power is applied to the modem, it will
0 - Disable, 1 -
Enable.
9 Appendix
Honeywell
| 69