CNI4

CNI4 Quick Start Guide 

FD-601 | Version 1 | September 2017 

Honeywell Process Solutions | Mercury Instruments 

512 Virginia Drive Ft. Washington PA 19034 USA 

855 251-7065 

 United States & Canada     |     302 669-4253 

 Outside the United States 

MI-TAC-Support@Honeywell.com

   |   www.honeywellprocess.com 

Summary of Contents for CNI4

Page 1: ...ion 1 September 2017 Honeywell Process Solutions Mercury Instruments 512 Virginia Drive Ft Washington PA 19034 USA 855 251 7065 United States Canada 302 669 4253 Outside the United States MI TAC Support Honeywell com www honeywellprocess com ...

Page 2: ... SIM Card Step 2 Power up the CNI4 battery or external power supply Step 3 Connect the external pulse inputs for wall mounted only Step 4 Disconnect the serial cable interfacing the Pulse Accumulator and the Cloud Link Step 5 Configure the Pulse Accumulator Step 6 Configure the Cloud Link 4G Modem Step 7 Restore the original serial cable connection Step 8 Close and lock the door Step 1 Open the do...

Page 3: ...r plug on the Cloud Link 5 Attach the connector from second battery to the Cloud Link battery connector 6 Wrap the extra wire using a cable tie To connect the battery pack to the Pulse Accumulator 1 Install the Pulse Accumulator battery pack on the left side of the battery plate 2 Connect the Pulse Accumulator battery pack to the Y cable 3 Wrap the extra wire using a cable tie The Pulse Accumulato...

Page 4: ...inal Block 2 of the Pulse Accumulator A 3 5 volts DC wetting voltage is provided by each Pulse Accumulator input channel If the pulse channel is to be wired to an active device i e transistor type output then be sure to observe polarity To connect the external pulse inputs 1 Remove the housing on the cable gland and route the pulse input s cable through it 2 Unplug the male 4 pin terminal block co...

Page 5: ...ctor of the Pulse Accumulator into the female connector of the USB to serial cable 2 Connect the USB end of the serial cable to a PC 3 Launch and login to the MasterLink desktop application 4 Navigate to the Settings menu set the baud rate to the recommended value 9600 and click OK 5 Click Connect to connect to the Pulse Accumulator Disconnect the RS232 connector from the Cloud Link 4G Modem ...

Page 6: ...Call in Trigger 3 Alarm Scheduled Call in 449 Switch Filtering 1 Filter Both Channels 486 Modem AT Command Enable 1 yes 334 Scheduled Call In Date Set the desired call in date 335 Scheduled Call In Time Set the desired call in time 336 Call In Retry By Instrument 339 Scheduled Call In Phone number IP Port Example 192 168 1 1 50467 485 Call Out Stop Time 00 00 00 490 Call Out Start Time 00 00 00 49...

Page 7: ... Insert the male connector so far unused of the USB to serial cable into the female RS232 connector slot on the Cloud Link 3 Click Connect to connect to the Cloud Link 4 Close the warning pop up enter site name and click Save 5 Wait for the dashboard to load Click the center of the Time Sync widget and perform a time synchronization between the Cloud Link and the PC by clicking Sync ...

Page 8: ...3 APN Name Provided by Verizon Example for AT T 12221 mcs 7 Cloud Link must be externally powered and modem session timeout must be configured to 180 seconds if MiWireless mode is enabled Item No Description Recommended Value 3142 MiWireless Enable 1 Enable 3028 Modem session timeout 180 seconds 8 Disconnect MasterLink 9 Power cycle the CNI4 Step 7 Restore the original serial cable connection 1 Di...