HONEYWELL 7000 SOLID STATE ALARM SYSTEM
69-1192—1
20
Customer Data Entry:
The following control panel options are listed as a checklist to
make sure customer database information is not left out.
Refer to Programming Instructions, form 24510169, for step-
by-step instructions with illustrations.
IMPORTANT
Do not program the Honeywell 7000 System to call a
fire or police station number unless authorized by
that fire or police station.
1.
Open the customers program or a new one if the
program doesn’t exist (default program).
2.
Establish or verify a customer three-digit ID (account)
number.
3.
Fill in the Customer information.
4.
Proceed to programmer options and fill in the name.
5.
Fill in CSC dial out prefix if applicable.
6.
Verify or add call-back number 1 to call the Central
Station.
7.
Verify or add call-back number 2 to call the Central
Station.
8.
Set city in the data base.
9.
Select Programmer type - Local or by modem remote.
10.
Enter the Comm. port of modem on PC.
11.
Verify or select Dial Method Tone or Pulse.
12.
Enter Modem Type.
13.
Enter R-Dial Type yes or no.
14.
Enter Modem speed - 300 or 1200.
IMPORTANT
The next step will send the program to the
customers Control Panel. Proceed to step 16 unless
you are ready to download information to the
System 7000.
15.
At Transfer Main Menu Programming Information
submenu enter the Customer’s Phone Number. This is
not required for local programming.
16.
Enter Customer’s Unit Account number - 001-999
17.
Enter Passcode length 4,5, or 6.
18.
Enter Duress Digit - 0-9.
19.
Select passcode required for MODES yes or no.
20.
Enter number of RF receivers - 0-2.
21.
Select allow remote programming. Yes or No.
22.
Select special Needs - Yes or No.
23.
Add the CSC Receiver telephone Number 1
24.
Specify delay seconds of report to CSC. - 00 to 99.
NOTE:
UL Requires this to be set to 0.
25.
Set dialing method pulse or tone.
26.
Force 6500 Transmission to ZONEX - yes or no. See
programming guide for details.
27.
Select if RF Troubles will be Reported. Yes or no.
28.
Fill in the Callback phone number 1. Number of CSC
modem phone line.
29.
Fill in the Callback phone number 2. Number of CSC
modem phone line. (Optional)
30.
Enter the Pick up phone after how many rings. 1 to 15.
IMPORTANT
Watch out for other devices on the line such as
answering machines, FAX machines and local
telephone company options.
31.
Enter the FIRE, POLICE, and SPECIAL Keypad point
numbers.
32.
Enter Fire Audible Shutoff. UL requires this to be set to
4 minutes or greater.
33.
Set Police, Special, and Tamper Audibles. Silent or not
silent.
34.
Set the Entry/ Delay times. 0 to 255 seconds.
35.
Pick customer city.
36.
If necessary, pick time zone. Previous step should
exclude need for this entry.
37.
Set daylight savings parameters. See Programming
guide.
38.
Set EVENT TRIGGERS OUTPUT for each customer
output. See Programming Guide.
39.
Set OUTPUT OPTIONS. Continuous or Momentary for
1 to 15 seconds. Bell/Horn output 1 is fixed continuous.
40.
Set up the 8 AREA names.
41.
Enter the points and how connected on each area/
zone.
42.
Define Point Type (Hardwire or RF), Hardwire Use, and
Loop Type.
43.
Enter each Serial Number for each RF Point Type
Transmitter. See marking on transmitter.
44.
Enter Loop Number for RF Point Types.
45.
Select RF Transmitter Type - Supervised, Non-sup or
Button.
46.
Attach points to areas and select Point Names for the
points.
IMPORTANT
Use only Ademco 5800 Series Transmitters on the
Honeywell 7000 Control Panel.
47.
Define Point Type (17 selections) see Programming
Guide.
48.
Define OUTPUT and MODES for each point. See
Programming Guide for details on Modes on points that
are Strategy Point Types.
49.
Repeat steps above as necessary to enter all points
into all zones in the system.
50.
In the MODES Menu select the first mode and define it.
MODES can be Special or Normal. The following two
steps are for Special Points. Skip to step 53 for Normal
MODES.
51.
Set Mode NAME, TYPE, PASSCODE LEVEL,
SPECIAL NEEDS, and OUTPUT ACTIVATION.
52.
If Mode is to have a Smart Point select which Smart
Point, then select CHANGE POINT and set the point to
ARM, DISARM, ON WATCH, or NO CHANGE.
53.
Set Normal Mode NAME, TYPE, PASSCODE LEVEL,
SPECIAL NEEDS, OUTPUT ACTIVATION, DELAY,
OCCUPANCY STATE, CHANGE POINT TO STATUS,
and CHANGE POINT STATUS TO.
54.
In the Passcodes Menus set up all 10 passscodes plus
the inactive or temporary, and attach an authority level.
(See Programming Guide for details)
55.
Download the Customer Data into the 7000 System by
selecting SEND PROGRAM in the TRANSFER MAIN
Menu.
56.
Wait for the message “PROGRAMMING
SUCCESSFUL”.
57.
Print out a hard copy of the Customer Data to verify
that all the sales options have been entered. Keep this
copy for history records. Save the customer data on the
PC’s hard disk.