HONEYWELL 7000 SOLID STATE ALARM SYSTEM
69-1192—1
2
ORDERING INFORMATION
When purchasing replacement and modernization products refer to the price sheets for complete ordering number.
If you have additional questions, need further information, or would like to comment on our products or services, please write or
phone:
1.
Your local Home and Building Control Sales Office (check white pages of your phone directory).
2. Home and Building Control Customer
Relations
Honeywell, 1
8
85 Douglas Drive North
Minneapolis, Minnesota 55422-4386
In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9.
International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France,
Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
SPECIFICATIONS
System 7000 Specifications
Electrical Ratings:
System Power:
115 Vac; 60 Hz, 0.5A.
Low voltage Input to Control Panel
24 Vac , 2A (50 VA, UL-listed, fused Class II Transformer)
NOTE:
24 AC Power wiring is limited to 20 feet of
No. 18 AWG wire.
Outputs:
No. 1 (Bell/Horn):
1A maximum at 13.8 Vdc.
No. 2 (AUX):
100 mA maximum at 13.8 Vdc.
Fusing:
Hbus: +13.8 Vdc, current limited at 2A.
AUX Horn: +13.8 Vdc, current limited at 2A.
Battery Charging Output:
800 mA maximum at 13.8 Vdc.
Power Consumption (at 13.8 Vdc):
Keypad 120 mA.
Point Expansion Module (PEM), 60 mA (120 mA when
both relays are on).
RF Expansion Module (RFEM), 60 mA.
Ademco Receiver, 50 mA.
Ademco Transmitters (see individual Ademco specification
sheet with each type of transmitter).
Battery Backup:
7AH Minimum, 28 AH Maximum at 12 to 13.8 Vdc.
Fuses:
One 2A, AGA2 fuse: F3 = AC.
Digital Communicator (Located on Control Panel)
Format: Modem 2E.
Line Seizure: Double Pole.
Ringer Equivalence: 1.0 B.
FCC Registration No.: B7FUSA-30171-AL-E.
Connection: RJ31X Type.
Circuit wiring:
Fire Circuit (Loop 8):
1000 feet, No. 18 AWG wire, 50 mA maximum,
for 10 two-wire smoke detectors.
Burglary circuits (Loop 1-7):
1000 feet maximum, No. 22 AWG wire.
End of Line Resistors (EOLR):
Inputs 1 through 7: 3.3 kilohm.
Input 8: 5.1 kilohm.
Four Wire HBus Interface (Cable No. 10-6608, 22 AWG)
Red: Power 13.8 VDC 1.0 amps maximum load.
Black: ground.
Yellow: (+) Data high.
Green: (-) Data low.
120 Ohm 5% 1/4 Watt end-of-line (EOL) resistor at end
of last bus device.
250 feet home run 22 AWG, 500 feet home run
18 AWG.
Environmental Ratings:
Ambient Temperature: 32
°
F (0
°
C) to 120
°
F (49
°
C).
Humidity: Less than 85% relative humidity, continuous,
noncondensing.
Dimensions:
Control Panel:
12-1/2 in. x 12-1/2 in. x 3-1/8 in.
Keypad, LCD Two Line:
6-13/32 in. x 5-11/32 in. x 29/32 in.
Point Expansion Module:
6-1/2 in. x 4-5/16 in. x 1-13/32 in.
RF Point Expansion Module:
6-1/2 in. x 4-5/16 in. x 1-13/32 in.
RF Receiver
7-3/8 in. x 4-3/8 in. x 1-7/16 in. (with antenna 10-7/8 in.
high).
Transmitters:
See individual Ademco specification sheet with each
type transmitter.