CONTRÔLEUR CONTROLINKS™ R7999C
32-00081EF—01
12
Fig. 6. Raccordement à Fireye E100/E110.
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
TEMP. EAU OU
CHEMIN
4-20 mA
LIMITEUR/CONTRÔLEUR
À SEMI-CONDUCTEURS 4-20 mA
A-1
A-2
CW
S
CCW
F1-1
F1-2
CW
S
CCW
F2-1
F2-2
CW
S
CCW
FG-1
FG-2
CW
S
CCW
MNC
XmA+
XmA–
CmA+
CmA–
CARBURANT 1
AIR
CARBURANT 2
FGR
MAX
MIN
RÉINIT. MIN.
(DISTANTE)
RS485 DDL
1
2
3
4
5
6
7
8
9
10
11
12
13
14
RÉGULATEUR
DE BRÛLEUR
FIREYE
(E100)
(E110)
CTRL
ENTRÉE LIMITES
FUEL
VALVE
ILK
DEMANDE
ALARME
ENTRÉE COMMUT. COMB. HAUTE
COMB. HAUTE
COM
COMB. BASSE
POTENTIOMÈTRE
D'ALLURE DE CHAUFFE
MANUEL 5 KOHMS
L1
(SOUS
TENSION)
L2
TERRE
Q7999
L1
G
L2
A/M
FS1
FS2
ALR
VCH
VCB
CH
VP
ENTRÉE DE
COMMANDE DE LIMITE
SORTIE DE
COMMANDE
DE LIMITE
SORTIE DE
COMMANDE
DE LIMITE
MF36824
MV
CONTACTEUR DE SÉLECTION DE CARBURANT
CARBURANT 1 mV
CARBURANT2 mV
1
1
1
1
5
1
1
2
3
4
7
3
2
2
41
42
43
44
45
46
FIL DE TERRE BLINDÉ À VIS DE TERRE DE PLAQUE CÔTÉ BASSE TENSION DE LA PLAQUE.
FUSIBLE TENSION SECTEUR VERS SYSTÈME DE RÉGULATION AVEC FUSIBLE SC15 OU FUSIBLE ENTRÉE LIMITE AVEC FUSIBLE SC5.
CONNECTEUR RS-485 DDL SUR CONTRÔLEUR R7999C.
CONTACTEUR DE SÉLECTION DE COMB. APPROUVÉ REQUIS (POS. ARR. CENTR.).
CONTACTEUR MOMENTANÉ NORM. OUVERT (CONNEXION ENTRE BORNES 35 ET 38). POTENTIOMÈTRE D'ALLURE
DE CHAUFFE MANUEL (CONNEXION ENTRE BORNES 36 ET 38).
POTENTIOMÈTRE D'ALLURE DE CHAUFFE MANUEL (CONNEXION ENTRE BORNES 36 ET 38).
UN RELAIS DE TENSION SECTEUR EXTERNE (120 V C.A.) DOIT ÊTRE AJOUTÉ ET CÂBLÉ COMME ILLUSTRÉ SUR LE CÔTÉ. LE RELAIS DE VANNE EXTERNE EST REQUIS
POUR RETARDER L'ENTRÉE DE VÉRIFICATION DE BASSE COMBUSTION VERS CONTROLINKS CAR LE RÉGULATEUR FIREYE
CONTRÔLE LA VÉRIFICATION DE COMBUSTION HAUTE ET BASSE EN MÊME TEMPS. CONTROLINKS NE PERMET PAS CETTE CONDITION.
RETIRER L'ENTRÉE DES SÉLECTEURS DE LIMITE LA BORNE 13 DU FIREYE ET RELIER À LA BORNE 13 DU Q7999
(ENTRÉE DE COMMANDE DE LIMITE) LE NON-RESPECT DE CETTE INSTRUCTION PEUT CAUSER UN ALLUMAGE PRÉMATURÉ.
RELIER LA BORNE 14 DU Q7999 (SORTIE DE COMMANDE DE LIMITE) À LA BORNE 13 DU FIREYE. SUIVRE LES INSTRUCTIONS DE CÂBLAGE DU FIREYE.
RELIER LE VERROUILLAGE DE VANNE DE COMBUSTIBLE ENTRE LA BORNE DU FIREYE ET LA BORNE 13 ET RELIER LE VERROUILLAGE DE MARCHE
ENTRE LES BORNES 3 ET P. LE NON-RESPECT DE CETTE INSTRUCTION PEUT CAUSER UN ALLUMAGE PRÉMATURÉ.
L1 L2 G
7
8
D
X
10
11
12
3 13
P
DR1
DR1
DR1
DR1
DR2
DR2
DR2
DR2
HORAIRE
HORAIRE
HORAIRE
HORAIRE
S
S
S
S
ML7999C
ML7999C
ML7999C
ML7999C
L1
D
9
L2
Q7999
FIREYE
(E100)
FIREYE
(E100)
RELAIS DE TENSION
SECTEUR EXTERNE
N.O.
5
6
7
8
9
9
8
7
6
1
4
9
RUNNING
ILK
RS485 DDL
RS232
(PC)
AFFICHAGE
SYSTÈME
S7999D1048
OU
RS485
(EXT)
OU
AUTO
MANUEL
CONVERTISSEUR
QM4520
RS232/RS485
USB VERS
RS-485
ANTI
HORAIRE
ANTI
HORAIRE
ANTI
HORAIRE
ANTI
HORAIRE