background image

Limited Warranty and Limitation Liability

BW Technologies LP (BW) warrants the product to be free from defects in material and workmanship under normal use and service for a period of two years, beginning on the date of shipment to the buyer. This 
warranty extends only to the sale of new and unused products to the original buyer. BW’s warranty obligation is limited, at BW’s option, to refund of the purchase price, repair or replacement of a defective 
product that is returned to a BW authorized service center within the warranty period. In no event shall BW’s liability hereunder exceed the purchase price actually paid by the buyer for the Product. 
This warranty does not include:

a) fuses, disposable batteries or the routine replacement of parts due to the normal wear and tear of the product arising from use;
b) any product which in BW’s opinion, has been misused, altered, neglected or damaged, by accident or abnormal conditions of operation, handling or use;
c) any damage or defects attributable to repair of the product by any person other than an authorized dealer, or the installation of unapproved parts on the product; or

The obligations set forth in this warranty are conditional on:

a) proper storage, installation, calibration, use, maintenance and compliance with the product manual instructions and any other applicable recommendations of BW;
b) the buyer promptly notifying BW of any defect and, if required, promptly making the product available for correction. No goods shall be returned to BW until receipt by the buyer of shipping instructions 

from BW; and

c) the right of BW to require that the buyer provide proof of purchase such as the original invoice, bill of sale or packing slip to establish that the product is within the warranty period.

THE

 

BUYER

 

AGREES

 

THAT

 

THIS

 

WARRANTY

 

IS

 

THE

 

BUYER

S

 

SOLE

 

AND

 

EXCLUSIVE

 

REMEDY

 

AND

 

IS

 

IN

 

LIEU

 

OF

 

ALL

 

OTHER

 

WARRANTIES

EXPRESS

 

OR

 

IMPLIED

INCLUDING

 

BUT

 

NOT

 

LIMITED

 

TO

 

ANY

 

IMPLIED

 

WARRANTY

 

OF

 

MERCHANTABILITY

 

OR

 

FITNESS

 

FOR

 

A

 

PARTICULAR

 

PURPOSE

BW

 

SHALL

 

NOT

 

BE

 

LIABLE

 

FOR

 

ANY

 

SPECIAL

INDIRECT

INCIDENTAL

 

OR

 

CONSEQUENTIAL

 

DAMAGES

 

OR

 

LOSSES

INCLUDING

 

LOSS

 

OF

 

DATA

WHETHER

 

ARISING

 

FROM

 

BREACH

 

OF

 

WARRANTY

 

OR

 

BASED

 

ON

 

CONTRACT

TORT

 

OR

 

RELIANCE

 

OR

 

ANY

 

OTHER

 

THEORY

.

Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not 
apply to every buyer. If any provision of this warranty is held invalid or unenforceable by a court of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision.

Contacting BW Technologies by Honeywell

Corporate Headquarters

BW Technologies by Honeywell

2840 2nd Ave. SE

Calgary, AB

Canada  T2A 7X9

Tel:

+1.403.248.9226

Toll-free: 1.800.663.4164

Fax:

+1.403.573.3708

United States

BW Technologies by Honeywell

405 Barclay Blvd.

Lincolnshire, IL

USA  60069

Tel:

+1.847.955.8200

Toll-free: 1.800.538.0363

Fax:

+1.847.955.8210

Europe

BW Technologies by Honeywell

4 Stinsford Road

Nuffield Industrial Estate

Poole, Dorset

United Kingdom  BH17 0RZ

Tel: +44 (0) 1295.700.300

Fax: +44 (0) 1295.700.301

Asia Pacific

Honeywell

 

Analytics

 

Asia

 

Pacific

#701

 

Kolon

 

Science

 

Valley

 

(1)

43

 

Digital

Ro,

 

34

Gil

 

Guro

Gu,

 

Seoul,

  

152

729

Korea
Tel:

 

+82

 

(0)2

 

6909

 

0300

Fax:

 

+82

 

(0)2

 

2025

 

0388

Email:

analytics.ap@honeywell.com

Email

info@gasmonitors.com

Web

www.gasmonitors.com

Summary of Contents for D4-PF-1

Page 1: ...User Manual Motorized Sampling Pump 50105442 056 English BW Technologies 2013 All rights reserved The Sampler ...

Page 2: ......

Page 3: ...ivating the Sampler 4 Normal Operation 4 Operating Guidelines 4 Standard Hose Configuration 5 Sample Tube Connections 5 Block the Airflow 5 Deactivating the Sampler 6 Alarms 6 Low Flow Alarm 6 Low Battery Alarm 6 System Fault Alarm 6 Calibration 6 Calibration Pass 6 Calibration Fail 6 Maintenance 7 Replacing the Batteries 7 Replacing a Filter 8 Draining the Water Trap 8 Troubleshooting 9 Replaceme...

Page 4: ......

Page 5: ... the buyer provide proof of purchase such as the original invoice bill of sale or packing slip to establish that the product is within the warranty period THE BUYER AGREES THAT THIS WARRANTY IS THE BUYER S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE BW SH...

Page 6: ...ogies by Honeywell and or Honeywell liable to anyone for any indirect special or consequential damages The information and specifications in this document are subject to change without notice The Sampler is a trademark s of Honeywell International Inc Other brand or product names are trademarks of their respective owners Signal Words This document uses the following signal words as defined by ANSI...

Page 7: ...BW Technologies single and multiple gas detectors An internal motorized pump transports potentially hazardous gases from a sample area to a detector The Sampler is an accessory for a personal safety device It is your responsibility to respond properly to alarm conditions Order Number Description GA SP01 Motorized sampling pump with rigid probe and sample tubing GA SP02 Motorized sampling pump with...

Page 8: ... using the recommended charger only Do not use any other charger Failure to observe this precaution could lead to fire or explosion Do not change or charge batteries in a hazardous location Doing so will impair the intrinsic safety of the unit and may lead to fire or explosion Read and observe all instructions and precautions in the literature provided with the charger Failure to do so may result ...

Page 9: ...ion mode the next time it is activated Calibration Confirm that the Sampler is on Press and hold C for 6 seconds to start calibration The Sampler beeps then deactivates The Sampler enters calibration mode the next time it is activated Airflow To block airflow through the Sampler firmly press the block trigger Note Airflow can also be blocked by tempo rarily kinking the hose or covering the end of ...

Page 10: ...uick reference card User Manual To order replacement parts refer to Replacement Parts and Accessories The Sampler is shipped with the short sample tube installed The Operation section describes how to replace the sample tube To install the batteries refer to Replacing the Batteries Activating the Sampler 1 To activate the Sampler press C 2 All 3 LEDs flash and the audible alarm beeps 4 times When ...

Page 11: ...until firm resistance is felt Block the Airflow Block the airflow to the Sampler to confirm that it is working correctly and there are no leaks in the system There are two ways for you to test the airflow of the Sampler 1 Press and hold the block trigger 2 Kink the sampling or attachment hose If the red FAIL LED blinks and the alarm beeps while the airflow is blocked then the Sampler is operating ...

Page 12: ...ower nears depletion If the battery voltage drops too low the audible alarm beeps once the red FAIL LED lights and the Sampler turns off Refer to Replacing the Batteries System Fault Alarm If the Sampler detects a system fault the red FAIL LED lights and the audible alarm beeps Press Cto clear the alarm The Sampler automatically enters the calibration mode If the Sampler passes calibration it will...

Page 13: ...lled in the Sampler Refer to Specifications for approved batteries Charge batteries using only a recommended charger Do not use any other charger Failure to observe this precaution could lead to fire or explosion Do not change or charge batteries in a hazardous location Doing so will impair the intrinsic safety of the unit and may lead to fire or explosion Deactivate the Sampler before replacing t...

Page 14: ...s firmly seated into the plug and the open end of the filter is facing out 3 Insert the filter plug assembly into the Sampler ensuring the filter enters the gasket filter opening Draining the Water Trap Empty the water trap periodically Pull open the drain plug and shake any water out of the water trap Replace the plug when complete Filter Filter plug Open end of filter Gasket filter opening Filte...

Page 15: ...er automatically turns off Automatic Shutdown feature activated due to weak batteries Replace batteries Sampler turns off with red FAIL LED flashing A blocked state was not triggered during calibration Activate the Sampler During calibration block the airflow of the Sampler when the yellow LED flashes There is water in the water trap Empty the water trap Filter is in backwards Remove the filter pl...

Page 16: ...w battery system fault Typical Battery Life Alkaline NiMH 30 hours at 25 C 77 F Altitude Up to 9843 ft 3000 m Pollution Degree 2 Installation Category I Approved Batteries North America IECEx Model No Description Qty GAMIC V CHRG1 12V vehicle charger and 4 AA NiMH batteries 1 GAMIC C01 K 110 VAC 4 port charger and 4 AA NiMH batteries 1 GAMIC C01 K xx 220 VAC 4 port charger and 4 AA NiMH batteries ...

Page 17: ...NiMH battery charger with country specific mains adapter Charge Time 1 3 hours Approvals Approved by CSA to both U S and Canadian Standards Class I Division 1 Group A B C and D Class I Zone 0 Group IIC IECEx Approval Ex ia IIC Ga IECEx CSA04 0003X ABS Type Approved VA 348 169 X ...

Page 18: ...The Sampler User Manual 12 ...

Page 19: ......

Page 20: ...User Manual Motorized Sampling Pump 50105442 056 Rev 3 English BW Technologies 2013 All rights reserved The Sampler ...

Reviews: