DB7110U UNIVERSAL HEAT PUMP DEFROST CONTROLLER

5

34-00032—01

COMPATIBILITY CHART

Table 2. Compatibility Chart. 

Amana

C64301-1

C6431001

Arcoaire

32312-00

3232140

Armstrong

39840B001

44614-0001

44614-002

46257-001

47181-001

R46257-001

R46614-002

R47181-001

39840B002

37967B001

37967B002

R46K6701

R44614-001

R44614-002

Artesian

10321-00

Carrier

150-83-6A

621-xxxx

CES0110063-00

CES0110063-01

CES0110063-02A CES0130024-00

CES0130024-01

CES0130076

HK25SZ359A

HK32EA001

HK32EA003

HK32EA007

HK32EA008

HK32FA003

HK32FA006

Coleman

3030A374

3030A364

3C30A374

Comfortmaker

1029-2

34332100

34332101

Evcon

9218-374

Fast

1093410

Goettl

305007

Goodman

1084-03-2022

1084-200D

20293901

B1226006

B1226008

LR40061

PCBDM101

PCBDM130

PCBDM133

PCBDM160

PCBDM101S

PCBDM130S

Heil Quaker

HQ1052727

Heil/Tempstar

1087952

1087953

1173636

CEPL130524-01

Honeywell

ST74A1004

ST74A1020

ST74A1038

ST74A1053

ST74C1002

ICM

DFORB24A21300 ICM300C

DFORB-AB1004

DFORF

DFOSP24A2

ICM301C

ICM302C

ICM303C

ICM304

ICM307

ICM316

ICM317

ICM318

ICM319

ICM320

ICM321

ICM322 ICM323

W1001-4

ICP

1052757

1069364

Interthem

6208800

Lennox

100269-01

100269-02

100269-04

100269-05

11K7101

1507N170027

29M0101

29M0201

30W87

33G9501

34M6301

46K67

56M3701

68I2901

68J8401

78H6801

84W8801

86G1601

97M81

LB-101263A

LB-101263B

11K71

97M8101

30W8701

34M63

29M01

56M37

HPXB15

68I84

68I29

78H68

Nordyne

620880

621301A

621579B

621579C

624519A

624608

624626

624633

624644

624656

624700

917012

917178

917178A

920338

624644R

6246440

624633R

6246330

Ranco

DT2

Rheem

47-102684-01

47-102684-02

47-102684-03

47-102684-04

47-102684-07

47-102684-08

47-102684-83

47-102685-01

47-102685-02

47-102685-03

47-102685-04

47-102685-05

47-102685-06

47-102685-84

47-21517-11

47-21517-13

47-21517-14

47-21517-16

47-21517-17

47-21517-18

47-21517-22

47-21517-23

47-21517-24

47-21517-82

47-21517-88

47-21517-92

47-21776-01

47-21776-06

47-21776-86

DDL-013002-0RH

DLL-013002-1RH DDL-0131020-1RH

DDL-017002-2RH DDL-017102-1RH

DDL-017702-1RH DDL-117702-3RH

DDL-122131-2RH 47-21517-12

47-21517-85

47-102685-87

47-102684-09

47-102685-07

47-21517-20

Robertshaw

DT2-1000

TD-10

SnyderGeneral

1395-329

CEBD430524-04B

Table 2. Compatibility Chart.  (Continued)

Summary of Contents for DB7110U

Page 1: ...bleshooting Fig 1 DB7110U1000 SPECIFICATIONS Electrical Ratings Input Voltage 24VAC 60Hz Max Input Current 200mA Compressor Contactor 1A 24VAC Outdoor Fan 1 2HP motor 5A full load 30A locked rotor 240VAC Aux Heat 1A 24VAC Reversing Valve 1A 24VAC All outputs rated for 100 000 operations All terminals except FAN IN and FAN OUT are NEC Class 2 low voltage Environmental Ratings Operating Temperature ...

Page 2: ...ess place the new coil sensor on the coil loop nearest the expan sion valve where refrigerant is entering the coil during the heating mode This location gives the largest temperature difference between the air 4 Ensure the coil sensor is clamped tightly to the coil It may be desirable to add insulation to the sensor to yield more accurate readings although this is generally not needed Fig 3 Coil S...

Page 3: ...must be shorted for compressor operation Never bypass protective pressure switches LPC 2 Terminals High pressure cutout switch these terminals must be shorted for compressor operation Never bypass protective pressure switches AUX Output to auxiliary emergency heat energized during a defrost cycle or when requested by W input COMPR 2 Terminals Output to compressor contactor energized by Y request R...

Page 4: ... energized 3 Press and hold the button until tESt appears on the display as shown below Fig 10 4 Verify the unit enters defrost mode Fig 11 The reversing valve will change states and the aux heat will be energized A few moments later the fan will be turned off If Reversing Delay is enabled the compressor will be turned off for the selected time and then turn back on to reduce noise The DB7110U wil...

Page 5: ...CM316 ICM317 ICM318 ICM319 ICM320 ICM321 ICM322 ICM323 W1001 4 ICP 1052757 1069364 Interthem 6208800 Lennox 100269 01 100269 02 100269 04 100269 05 11K7101 1507N170027 29M0101 29M0201 30W87 33G9501 34M6301 46K67 56M3701 68I2901 68J8401 78H6801 84W8801 86G1601 97M81 LB 101263A LB 101263B 11K71 97M8101 30W8701 34M63 29M01 56M37 HPXB15 68I84 68I29 78H68 Nordyne 620880 621301A 621579B 621579C 624519A ...

Page 6: ...T02935 CNT03715 CNT03716 CNT04362 CNT04363 CNT04364 CNT04366 CNT04368 CNT04695 CNT05001 CNT05008 CNT05009 CNT05010 CNT05482 CNT05875 CNT1108 CNT01693 Weatherking 840 4 5548 White Rodgers 840 4 5548 47D40 801 47D43 101 47D43 111 47D43 11102 47D43 811 90 621 47D01U 843 York 031 00872 001 031 00872 002 031 00872 002 031 00872 701 031 00872 702 031 00872 703 031 01222 000 031 01251 000 031 01268 000 0...

Page 7: ...mbered parameter has a selectable value according to the table below For example would represent Parameter 1 Defrost Enable Temperature set to 35 degF Display Description Current Fault s Present Right digits blank if there is no fault and to scroll through active faults Fault History and to scroll through history Press and hold for more than two seconds to clear all inactive faults Table 4 Configu...

Page 8: ... Termination Temperature but a defrost cycle should never last longer than this time 8 14 minutes 14 minutes 8 Aux Heat Lockout Temperature W requests will be ignored if the outdoor temperature is higher than this temperature The Aux heat output will still function normally during a defrost cycle regardless of this setting Do not set this temperature below the Compressor Lockout Temperature or the...

Page 9: ... to run Never bypass protective pressure switches Check coil sensor the system will not run without a coil sensor Control displays DLY The system is in a startup delay due to short cycle protection powerup or low voltage Wait for the delay to expire Compressor does not stop when the call for heat or cool ends Observe display for current operational mode Control displays current mode OFF HEAT or CO...

Page 10: ...are correct Increase the Termination Temperature to allow the coil to get hotter before a defrost cycle is terminated Increase the Maximum Defrost Time to allow a defrost cycle to run longer System defrosts too much Observe defrost cycle Defrost triggers too frequently even with little or no ice buildup Verify sensor placement and readings are correct Decrease the Enable Temperature to force the c...

Page 11: ...h Pressure Cutout is currently open Investigate refrigerant charge Check indoor coil for blockage Check outdoor coil for blockage 8 Low Pressure Cutout is currently open Investigate refrigerant charge 9 Coil Sensor Open Circuited Check the sensor hasn t become unplugged Check sensor wiring Replace sensor 10 Coil Sensor Shorted Check for pinched wires Replace sensor 11 Air Sensor Open Circuited Che...

Page 12: ... Resideo Technologies Inc All rights reserved The Honeywell Home trademark is used under license from Honeywell International Inc www resideo com Resideo Inc 1985 Douglas Drive North Golden Valley MN 55422 34 00032 01 M S 12 18 Printed in United States ...