Manufacturer’s Name and Trademark
Product Name
and Part Number
Certified Ambient
Temperature
Modification Status
Warning
Certification
Type
Serial Number
Control
Number
WARNING:- SUBSTITUTION OF COMPONENTS
MAY IMPAIR INTRINSIC SAFETY.
V max: 32Vdc.
I max: 2A.
1 2 3 4 5 6 7
Amb.Temp.Range
-25 C to +40 C (UL)
-55 C to +40 C (CSA)
o
o
o
o
Mod.State
Ser.No. NNNN
T E R M I N AT I O N U N I T T Y P E D X 1 0 0 ( I )
PA R T N o . 2 1 0 4 B X X X X
CLASSIFIED AS TO FIRE, ELECTRICAL SHOCK &
EXPLOSIVE HAZARDS ONLY. FOR USE IN CLASS 1,
GROUPS B,C,D. PROVIDES INTRINSICALLY SAFE
CIRCUITS WHEN INSTALLED IN ACCORDANCE WITH
CONTROL DRGS. 2104E0097 (CSA) OR 2104E0045 (UL).
zellweger analytics
Z
sieger
C
LA
SSIFIED
93X0
Exia
Z
T E R M I N AT I O N U N I T T Y P E D X 1 0 0 ( I )
PA R T N o . 2 1 0 4 B 4 X X X
zellweger analytics
Z
sieger
Z
CLASSIFIED AS TO FIRE, ELECTRICAL SHOCK &
EXPLOSIVE HAZARDS ONLY. FOR USE IN CLASS 1,
GROUPS B,C,D. PROVIDES INTRINSICALLY SAFE
CIRCUITS WHEN INSTALLED IN ACCORDANCE WITH
CONTROL DRAWING 2104E0015.
1 2 3 4 5 6 7
Mod.State
Ser.No. NNNN
V max: 32Vdc.
I max: 2A.
Amb.Temp.Range
-25 C to +40 C
o
o
C
LA
SSIFIED
93X0
WARNING:- SUBSTITUTION OF COMPONENTS
MAY IMPAIR INTRINSIC SAFETY.
NOTES:
1.
APP
ARA
TUS
WHICH
IS
UNSPECIFIED
EXCEPT
THA
T
IT
MUST
NOT
BE
SUPPLIED
FROM,
NOR
CONT
AIN
IN
NORMAL
OR
ABNORMAL
CONDITIONS
A
SOURCE
OF
POTENTIAL
WITH
RESPECT
T
O
EAR
TH
IN
EXCESS
OF
250V
rms
OR
250V
d.c.
2.
WIRING
FROM
THE
HANDHELD
CALIBRA
T
OR
(SHC1)
T
O
THE
TERMINA
TION
UNIT
(DX100)
IS
NOT
T
O
EXCEED
15
METRES
MAX.
3.
INST
ALL
EQUIPMENT
INCLUDING
FIELD
WIRING
IN
ACCORDANCE
WITH
AR
TICLES
OF
THE
NA
TIONAL
ELECTRICAL
CODE
FOR
DIVISION
1
HAZARDOUS
LOCA
TIONS.
TRANSMITTER
ENTR
Y
(CONDUIT
CONNECTION
REQUIRED
WITH
SEAL)
OPTIONAL
TRANSMITTER
SEARCHLINE
EXCEL
FILE
No.
E91044
TERMINA
TION
UNIT
DX100
(I)
UL
FILE
E136193
COMMUNICA
TIONS
FIXED
SOCKET
I.S.
OUTPUT
T
O
CALIBRA
T
OR.
(F
ACT
OR
Y
FITTED)
SENSOR
ENTR
Y
(CONDUIT
CONNECTION
REQUIRED
WITH
SEAL)
SENSOR
ANY
SUIT
ABLE
UL
LISTED
OR
CLASSIFIED
EXPLOSION
PROOF
APP
ARA
TUS.
HANDHELD
CALIBRA
T
OR
TYPE
SHC
1
UL
FILE
E136193
NOTE
2
SUPPL
Y
ENTR
Y
(CONDUIT
CONNECTION
REQUIRED
WITH
SEAL)
HAZARDOUS
(CLASSIFIED)
LOCA
TION
CLASS
1,
DIV
.
1
GROUPS
B,C,D.
NON
HAZARDOUS
AREA
CONTROL
EQUIPMENT
NOTE
1
1.
2.
3.
1.
2.
HAZARDOUS
(CLASSIFIED)
LOCA
TION
CLASS
1,
DIV
.
1
GROUPS
B,C,D.
TERMINA
TION
UNIT
DX100
(I)
CSA
FILE
LR48148
SENSOR
ENTR
Y
(CONDUIT
CONNECTION
REQUIRED
WITH
SEAL)
COMMUNICA
TIONS
FIXED
SOCKET
I.S.
OUTPUT
T
O
CALIBRA
T
OR.
(F
ACT
OR
Y
FITTED)
SENSOR
ANY
SUIT
ABLE
CSA
CER
TIFIED
OR
CLASSIFIED
EXPLOSION
PROOF
APP
ARA
TUS.
HANDHELD
CALIBRA
T
OR
TYPE
SHC
1
CSA
FILE
LR48148
NOTES:
1.
APP
ARA
TUS
WHICH
IS
UNSPECIFIED
EXCEPT
THA
T
IT
MUST
NOT
BE
SUPPLIED
FROM,
NOR
CONT
AIN
IN
NORMAL
OR
ABNORMAL
CONDITIONS
A
SOURCE
OF
POTENTIAL
WITH
RESPECT
T
O
EAR
TH
IN
EXCESS
OF
250V
rms
OR
250V
d.c.
2.
WIRING
FROM
THE
HANDHELD
CALIBRA
T
OR
(SHC1)
T
O
THE
TERMINA
TION
UNIT
(DX100)
IS
NOT
T
O
EXCEED
15
METRES
MAX.
3.
INST
ALL
EQUIPMENT
INCLUDING
FIELD
WIRING
IN
ACCORDANCE
WITH
CANADIAN
ELECTRICAL
CODE,
P
AR
T
1.
NOTE
2
CONTROL
EQUIPMENT
NOTE
1
NON
HAZARDOUS
AREA
SUPPL
Y
ENTR
Y
(CONDUIT
CONNECTION
REQUIRED
WITH
SEAL)
DX100 (I) Termination Unit
Quick Start Guide
Issue a3 03/2017
H_MAN0618_V1
2140M0702
© 2017 Honeywell Analytics
11178
Please Note:
While every effort has been made to ensure accuracy in this
publication, no responsibility can be accepted for errors or omissions.
Data may change, as well as legislation, and you are strongly advised
to obtain copies of the most recently issued regulations, standards,
and guidelines.
This publication is not intended to form the basis of a contract.
© 2005 Honeywell Analytics
Find out more at:
www.honeywellanalytics.com
Contact Honeywell Analytics:
Europe, Middle East, Africa
Life Safety Distribution GmbH
Javastrasse 2
8604 Hegnau
Switzerland
Tel: +41 (0)44 943 4300
Fax: +41 (0)44 943 4398
gasdetection@honeywell.com
Customer Service
:
Tel: 00800 333 222 44 (Freephone number)
Tel: +41 44 943 4380 (Alternative number)
Fax: 00800 333 222 55
Middle East Tel: +971 4 450 5800 (Fixed Gas Detection)
Middle East Tel: +971 4 450 5852 (Portable Gas Detection)
Americas
Honeywell Analytics Inc.
405 Barclay Blvd.
Lincolnshire, IL 60069
USA
Tel: +1 847 955 8200
Toll free: +1 800 538 0363
Fax: +1 847 955 8210
detectgas@honeywell.com
Asia Pacific
Honeywell Analytics Asia Pacific
#701 Kolon Science Valley (1)
34 Worldcup Buk-ro, Mapo-gu,
Seoul 03922,
Korea
Tel: +82 (0)2 6909 0300
Fax: +82 (0)2 2025 0328
India Tel: +91 124 4752700
analytics.ap@honeywell.com
Technical Services
EMEA:
HAexpert@honeywell.com
US:
ha.us.service@honeywell.com
AP:
ha.ap.service@honeywell.com
www.honeywell.com
©2016 Life Safety Distribution
GmbH. All rights reserved.
This document contains
proprietary information of Life
Safety Distribution AG and its
affiliated companies and is
protected by copyright and other
international laws. Reproduction
or improper use without specific
written authorization of Life
Safety AG is strictly forbidden.
Honeywell Analytics Inc.,
Lincolnshire.
Made in USA