Project planning information for indirect heating
7 .3 Flue gas channelling
A flue gas connector FLUP, which is to be ordered sepa-
rately, is available as standard to channel flue gas in
an indirect heating system. In special cases, an educ-
tor EJEK can also be installed to channel flue gas. This
also must be ordered separately.
Flue gas connector FLUP
SER-C
SICAFLEX
FLUP
ECOMAX..C
Flue gas connector FLUP serves to discharge the flue
gases into the furnace flue gas system and features an
opening which is closed by a clip to connect flue gas
analysis equipment.
Eductor EJEK
SER-M
EJEK
SICAFLEX
In indirect heating systems with metal radiant tubes,
eductor EJEK can generate a negative pressure in the
radiant tube. This prevents the inert gas atmosphere in
the furnace being contaminated by flue gases from the
burner in the event of leakage from the single ended
radiant tube.