background image

Y

OUR NEW 

Electr

ode Steam

Honeywell wants to make sure you know what to expect from your new Electrode Steam installation. Make sure 
you discuss these items with your Professional Installer:

•  Achieving Humidity Setpoint. It may take up to a week of continuous operation to initially achieve the 

humidity setpoint. This depends on factors such as weather, size of home, furnishings in the home, and 
insulation. Once this is achieved, the Electrode Steam should not have to run as much to maintain humidity.

• 

On/Off Noise. When the humidifier starts up after being off, the unit will run a self-test sequence and may a 
“click” noise, engaging the fill & drain valves. This is normal .

•  Ideal Humidity. 35% relative humidity in typical winter weather is considered ideal for indoor comfort by 

industry experts. You can adjust to your own comfort or until there is condensation on the windows. Lower the 
setpoint if condensation appears.

•  Unit Not Humidifying. If the Electrode Steam is not running but the humidity is below the desired setting, the 

humidity control may have a frost protection setting. See “What is a frost setting?” on page 10. The Cylinder 
may also be at the end of its life, in which case you will be notified by the LED sequence. 

•  Setpoint Not Reached. If humidity doesn’t reach the setpoint, the Electrode Steam may be under-sized for the 

home. This can be due to insulation, windows, arid climate, and other environmental factors. Also, the outdoor 
temperature may be too low to maintain the humidity level. 

•  Home Ventilation. Excessive ventilation exhausts humidified air and replaces it with dry air. This can make it 

hard to maintain the humidity setpoint. If you are installing a ventilator, use a solution that retains moisture. An 
Energy Recovery Ventilator (ERV) is recommended.

• 

LED Status Lights. The HM700 user interface includes 2 LEDs that provide information about the humidifier 
status. Please see “What do the lights tell me?” on page 11 for more information.

• 

Water Draining. It is normal for the Electrode Steam to periodically drain some water automatically. This is 
due to the humidifier maintaining the perfect level of water conductivity and steam output.

•  Water Conductivity. Your home’s water conductivity determines how quickly the Electrode Steam will produce 

steam and also how often the replacement steam cylinder needs to be replaced.

•  Energy Consumption. You may notice a slight increase in overall energy consumption when operating 

any humidifier. However, the Electrode Steam will make the home feel warmer. This allows you to lower the 
temperature setting on the thermostat. Every degree lower on the thermostat can save up to 3% on heating 
costs.

What should I expect from my Electrode Steam?

Steam Humidification System   33-00165—01

8

Summary of Contents for Electrode Steam

Page 1: ...HOMEOWNER S OPERATING MANUAL Electrode Steam Homeowner s Manual 33 00165 01 ...

Page 2: ......

Page 3: ...should I get started 3 How does the Electrode Steam work 4 YOUR NEW Electrode Steam Which Electrode Steam model do I have 5 Which humidity control do I have 6 How is my Electrode Steam installed 6 Remote mounting 6 What Electrode Steam parts do I need to know 7 What should I expect from my Electrode Steam 8 EVERYDAY OPERATION How do I operate the Electrode Steam 9 How do I use the humidity control...

Page 4: ...ank or cover If in doubt turn off the breaker which is operating the Electrode Steam and disconnect HVAC equipment power before servicing CAUTION Heavy Equipment and Water Hazard Improper installation or misuse can cause death blindness and water damage to home Be sure you know how to turn the Electrode Steam off and how to drain the water tank safely CAUTION Steam Condensation and Freezing Water ...

Page 5: ...he Electrode Steam have Separate sensors and water monitoring via the electrodes and software monitor water within the tank These two important components prevent the tank from being over filled running dry and optimize steam production with various water qualities The auto adaptive feature monitors the Electrode Steam humidifier s water supply current and load The unit also self tests on a regula...

Page 6: ...cause of scale formation it will no longer be possible for the humidifier to reach its full capacity The Electrode Steam software monitors this condition and when detected will stop operating and flash the yellow LED in a repeating sequence of 4 flashes Drains As steam is produced minerals are left behind increasing the conductivity of the water The Electrode Steam patented auto adaptive cycle wil...

Page 7: ...ume of space width x length x height Also take into consideration the tightness of a home s construction Table 1 AHRI Recommended Humidity in gallons per day Construction Type 8 000 ft3 12 000 ft3 16 000 ft3 20 000 ft3 24 000 ft3 28 000 ft3 32 000 ft3 Tight 3 3 4 3 5 4 7 5 9 6 11 7 16 Average 7 6 9 6 11 8 16 20 3 24 4 33 Loose 11 7 14 9 18 1 24 5 30 8 37 1 50 Table 2 Steam humidifier s necessary f...

Page 8: ...l Your HVAC Professional Installer will install the Electrode Steam in a proper location in your home The best location depends on your furnace type and configuration and how your living space is arranged around the furnace ducts Your Electrode Steam will be remote mounted Remote mounting The Electrode Steam is installed some distance away from your furnace supply duct An insulated hose carries st...

Page 9: ...Cylinder Current heats the water inside the cylinder to make steam HumidiPRO Digital Control Controls humidity levels and turns on off the Electrode Steam Steam Hose Conduit to transfer the steam from the humidifier to the distributor On Off Drain Switch Turns power on off to humidifier controller and drains the cylinder Steam Humidification System 33 00165 01 7 M35762 ...

Page 10: ...ach the setpoint the Electrode Steam may be under sized for the home This can be due to insulation windows arid climate and other environmental factors Also the outdoor temperature may be too low to maintain the humidity level Home Ventilation Excessive ventilation exhausts humidified air and replaces it with dry air This can make it hard to maintain the humidity setpoint If you are installing a v...

Page 11: ...he control will call for humidity Some controls will also monitor outdoor conditions to ensure indoor humidity does not condense on windows and walls Refer to the manual provided with your humidity control for instructions on setting the control There are two different types of humidity control How do I operate the Electrode Steam Steam Humidification System 33 00165 01 9 Thermostat with integrate...

Page 12: ...ost from appearing on the inside of your windows Lower the frost setting by one value each morning that you see frost or condensation on windows Allow 24 hours for the new setting to take effect before re adjusting Once you have this set to a comfortable level without condensation you will not need to adjust further You can adjust your humidity setpoint without worrying about condensation Manual h...

Page 13: ...ered but the control equipment stat air proving fan etc has interrupted the call for humidity Yellow LED On Indicates that water level is high When the yellow LED is steady on not flashing it indicates that the high water sensor has interrupted filling of the cylinder The LED is on for information only and unless it persists for an extended period of time it does not require any action Green LED O...

Page 14: ...n though the Electrode Steam s water tank will drain automatically after several days Honeywell recommends shutting off the Electrode Steam water supply and turning off the humidity control for extended leaves Upon return turn on the water supply and reset the control to the desired setpoint What should I do at the end of the season The lights will blink when the internal dignostics systems needs ...

Page 15: ...red while the product was in the possession of a consumer Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT So...

Page 16: ...ontrol Solutions Honeywell International Inc 1985 Douglas Drive North Golden Valley MN 55422 http yourhome honeywell com U S Registered Trademark 2015 Honeywell International Inc 33 00165 01 M S 11 15 Printed in U S A ...

Reviews: