Metering Lines (4)
6 - 5
Model 1010 Application Pack CB
Part No.: 4418024 - Rev. 1
Programming Manual
Special (C)
Lube Oils (D)
NGL AND LPG (E)
FAME (F)
Meter n
Temp Sensor Type
Selects which type of temperature sensor to be used for temperature
correction.
Constraints:
Only available when you use the Weights and Measures switch on
the instrument to enter programming mode.
Only if commodity type is not none.
Select one of the following options:
4-20 mA*
RTD
Meter n
4 mA Temp
The temperature that corresponds to a 4 mA reading from the
temperature probe associated with this metering line.
Constraints:
Only available when you use the Weights and Measures switch on
the instrument to enter programming mode.
Only if Temp. Sensor = 4-20 mA
Enter a value in the following range:
NOTE:
Use the Arm key to toggle between negative and positive values.
Meter n
20 mA Temp
The temperature that corresponds to a 20 mA reading from the
temperature probe associated with this metering line.
Constraints:
Only available when you use the Weights and Measures switch on
the instrument to enter programming mode.
Only if Temp. Sensor = 4-20 mA
Enter a value in the following range (Whichever of the following options
is lesser):
4 mA setting to 4 mA s100 °C (for METRIC units)
Table 6-1: Commodity Based Temperature Range
Units
Base
Temp
Crude
Oils
(A)
Refined
(B)
Special
(C - thermal
exp.)
Lube
Oils
(D)
NGL and
LPG
(E)
FAME
°F
60 °F
-58.0 to 302.0
-50.8 to 199.4
N/A
°C
15 °C
-50.00 to 150.00
-46 to 93
20 to 60
20 °C
N/A