18
Installing the Scan Assembly
Setting the Baud Rate and Parity (SW6)
The baud rate and parity settings are determined by the protocol that you have
selected.
lists the baud rate and parity settings that go with each
protocol.
The baud rate and parity are set using DIP switch SW6 (see
). The
factory default is 9600 baud, even parity.
Table 3-3
Baud Rate and Parity Settings by Protocol
Protocol
Baud Rate and Parity
IntelliBus™
38400 baud, no parity
MAXPRO-mode (default)
9600 baud, even parity
VCL - RS485
9600 baud, no parity
Diamond
9600 baud, even parity
Pelco P
4800 baud, no parity
Pelco D
2400 baud, no parity
Table 3-4
SW6 Baud Rate and Parity Settings
Values
Baud Rate Switch Position
Parity Switch
Position
Other*
1
2
3
4
5
6
7
8
600
OFF
OFF
OFF
OFF
1200
ON
OFF
OFF
OFF
2400
OFF
ON
OFF
OFF
4800
ON
ON
OFF
OFF
9600
OFF
OFF
ON
OFF
19200
ON
OFF
ON
OFF
38400
OFF
ON
ON
OFF
57600
ON
ON
ON
OFF
115200
OFF
OFF
OFF
ON
None
OFF
OFF
OFF
OFF
Even
ON
OFF
OFF
OFF
Odd
OFF
ON
OFF
OFF
* The default position for pins 7 and 8 is OFF (see
).
Summary of Contents for EQUIP Series
Page 6: ...vi ...
Page 10: ...x ...
Page 12: ...xii Figures ...
Page 14: ...xiv Tables ...
Page 18: ...xviii ...
Page 56: ...36 Preparing to Configure the Dome ...
Page 120: ...100 Configuring Video ...
Page 130: ...110 System Administration and Equipment Handling ...
Page 147: ......