Power up and bind a Mixing Valve
Controller (HM80)
A Mixing Valve Controller should only be fitted by a qualified
fitter. Unless you’re using the
evohome
Controller as a sensor,
you need to install a sensor (HCW82, HCF82 or DTS92)
before binding the controller to the
evohome
Controller.
To bind the Digital Room
Temperature Sensor (DTS92)
1
Press and hold the power button for 2
seconds to put the unit into standby
2
Press the up and down arrows together for
three seconds – it should say INst
3
Press the down arrow – it should say COnt
4
Press the up arrow three times – it should say CLr
5
Press the power button once to clear
any previous binding data
6
Press the up arrow – it should say COnt
7
Press the power button once to send the
binding signal to the evohome Controller
8
You should receive a SUCCESS message on the
evohome Controller (if not go back and re-bind)
If you are NOT following
GUIDED CONFIGURATION
follow these steps on your
evohome
Controller display
once the Mixing Valve
Controller and sensor have
been installed:
1. On the evohome
Controller press and
hold “Settings” for 3
seconds
2. Press the green tick
3. Select ADD A ZONE
4. Select the zone you’re
adding the controller to
then select MIXING VALVE
5. If you want to control the
zone temperature with
your evohome Controller
(the evohome Controller
needs to be located in
that zone) YES, otherwise
press NO and bind the
sensor.
evohome
Controller
CONTINUED ON NExT PAGE
HOlD
3 SEC
2
Mixing Valve Controller (HM80)
27
evohome
Installation Guide