PROCESS INFORMATION DISPLAYS
6510020335
162
Table. 17.
Scanner Control Panel Buttons
Button/Switch Mode/Position
Function
Scan
ON - Computer
Mode
1
Starts scanning.
ON
–
Manual Mode
Starts scanning toward the motor end
support.
Off Sheet
ON - Computer
Mode
2
Closes all sensor shutters, disables sensors,
and sends the heads off-sheet at a faster
rate (by signaling the motor controller) and
takes the heads off line. Scanning can only
be resumed be pressing SCAN locally at the
scanner.
ON
–
Manual Mode
Starts scanning toward the cable end
support.
CALIPER
ENABLE
Sends a signal to the system to indicate that
the Caliper sensor can be enabled. This
triggers the sensor to close onto the sheet.
X-RAY
OFF
Disables power to the ash sensor x-ray
source
RESET
Resets the ash sensor X-ray source. It is
required that the sensor be RESET prior to
enabling power.
ON
Enables power to the ash sensor X-ray
source (after using RESET).
1
An Authorized Service Representative sets the mode of the scanner. A scanner can be in
either COMPUTER mode (usually for normal operation) or MANUAL mode (usually for
service). The mode change is not under Operator control.
2
An Authorized Service Representative sets the mode of the scanner. A scanner can be in
either COMPUTER mode (usually for normal operation) or MANUAL mode (usually for
service). The mode change is not under Operator control.
Summary of Contents for Experion MX
Page 1: ...Experion MX RELEASE 702 1 Operators Guide 6510020335 Rev 02 May 2019 ...
Page 7: ...6510020335 7 8 NOTICES 168 ...
Page 20: ...SCANNER SAFETY AND LOCAL CONTROLS 6510020335 20 Fig 15 Cable End Voltage Zones ...
Page 21: ...SCANNER SAFETY AND LOCAL CONTROLS 6510020335 21 Fig 16 Distant End Voltage Zones ...
Page 124: ...PROCESS INFORMATION DISPLAYS 6510020335 124 Fig 105 Profile Display ...
Page 159: ...PROCESS INFORMATION DISPLAYS 6510020335 159 Fig 148 Precision Platform 4000 01 Scanner ...
Page 160: ...PROCESS INFORMATION DISPLAYS 6510020335 160 Fig 149 Precision Platform 4000 20 21 Scanner ...