Attention
•
You can also configure net tag names through Bulk Build operation. To do so, you must configure the
NETTAGPDCNAME and the NETTAGNAME parameters. The NETTAGPDCNAME contains the net tags for
the slave devices configured in “Profibus Network Configuration Tool”. This parameter contains net tags starting
from index 1 (NETTAGPDCNAME[1]) in the Bulk Build XLS file. If you do not configure this parameter,
NETTAGNAMEs for the PDCs are not assigned in the DSB on creating and assigning it to the Protocol Block
through the Bulk Build tool.
•
You cannot configure NETTAGPDCNAME[0] since element at index 0 is always empty and is used for
deselecting the configured NETTAGNAMEs in the PDC tab of the DSB. If you try to do so, an error message
appears.
•
Whenever you reconfigure net tags for a PDC, you must reload the DSB before removing the same net tag in
Sycon and reloading the Protocol Block. This prevents the DSB or the PDC from going into error state during run
time while modifying the net tag usage.
1
Click the
Process Data
menu in the
Navigation Area
.
The slave devices that you have selected appear in the right pane.
2
Click
to view the input and output modules associated with the specific device.
By default, the field network tags appear as Input_* or Output_* depending on whether the device is an
input module or an output module.
3
Select the field network tag in the
Tag
column and modify the tag name. If you do not modify the default
network tags, only the first default name for each input/output is used.
The following figure displays a sample
Address Management
page that replaces the
Process Data
page
and the
Address Table
pagein Experion R410.2 and later.
6 PROTOCOL BLOCK
73
Summary of Contents for Experion PKS
Page 1: ...Experion PKS PROFIBUS Gateway Module User s Guide EPDOC XX88 en 431E June 2018 Release 431 ...
Page 8: ...CONTENTS 8 www honeywell com ...
Page 10: ...1 ABOUT THIS GUIDE 10 www honeywell com ...
Page 32: ...4 PROFIBUS GATEWAY MODULE PGM INSTALLATION 32 www honeywell com ...
Page 58: ...5 PROFIBUS GATEWAY MODULE PGM BLOCK 58 www honeywell com ...
Page 69: ...6 PROTOCOL BLOCK 69 ...
Page 103: ...5 Click OK 6 PROTOCOL BLOCK 103 ...
Page 110: ...6 PROTOCOL BLOCK 110 www honeywell com ...
Page 183: ...PDC Details tab Figure 6 Detail Display of PDC Details tab 7 DEVICE SUPPORT BLOCK DSB 183 ...
Page 186: ...7 DEVICE SUPPORT BLOCK DSB 186 www honeywell com ...
Page 231: ...9 PROFIBUS I O MODULE PIOMB FUNCTION BLOCK 231 ...
Page 232: ...9 PROFIBUS I O MODULE PIOMB FUNCTION BLOCK 232 www honeywell com ...
Page 236: ...10 PROFIBUS GATEWAY MODULE PGM CONFIGURATION EXAMPLE 236 www honeywell com ...