Field Network Master State (MASTERSTATE)
The MASTERSTATE parameter displays the state of the field network master.
Slave State (SLAVESTATE)
The SLAVESTATE parameter indicates whether the master is in cyclic data exchange to all the configured slave
devices.
Field Network State (BUSSTATE)
The BUSSTATE parameter indicates the current network status of the communication channel.
Global State (GLOBALSTATE)
The GLOBALSTATE parameter serves as a collective display of the global notifications. The notified errors can
occur either at the PROFIBUS master itself or at the slave devices.
6.10.3 Protocol Block command parameters
Compact Non-Volatile Storage (COMPNVSCMD)
The COMPNVSCMD parameter indicates whether to compact the non-volatile memory or not.
6.10.4 Protocol block statistics parameters
The
DPV1 Statistics
tab is added in the Protocol block’s configuration form for monitoring the DPV1 statistics
information. The statistics information related to the DPV1 connection is monitored from the
Class 2
Connection Status
table.
DPV1 Bytes per sec (DPV1BYTESPERSEC)
The DPV1 Bytes per sec (DPV1BYTESPERSEC) parameter provides the DPV1 traffic in bytes per second per
link level.
DPV1 Requests per sec (DPV1REQSPERSEC)
The DPV1 Requests per sec (DPV1REQSPERSEC) parameter provides the DPV1 traffic in requests per second
(HOP and DPV1) per link level.
DPV1 Connection Status (DPV1CONNSTS)
The DPV1 Connection Status (DPV1CONNSTS) parameter provides the DPV1 connection status of the
PROFIBUS slave devices.
DPV1 Connection Ref ID (DPV1CONNREF)
The DPV1 Connection Ref ID (DPV1CONNREF) parameter displays the DPV1 connection ID for a slave.
Attention
A valid connection ID is displayed only when the DPV1 connection status to a slave is set as “Connected.”
DPV1 Req last error code (LASTERRCODE)
The DPV1 Req last error code (LASTERRCODE) parameter displays the last error code received for DPV1
connection to a slave.
For more information about the connection status of DPV1 request, see
PROFIBUS Gateway Module
Parameter Reference
.
6 PROTOCOL BLOCK
92
www.honeywell.com
Summary of Contents for Experion PKS
Page 1: ...Experion PKS PROFIBUS Gateway Module User s Guide EPDOC XX88 en 431E June 2018 Release 431 ...
Page 8: ...CONTENTS 8 www honeywell com ...
Page 10: ...1 ABOUT THIS GUIDE 10 www honeywell com ...
Page 32: ...4 PROFIBUS GATEWAY MODULE PGM INSTALLATION 32 www honeywell com ...
Page 58: ...5 PROFIBUS GATEWAY MODULE PGM BLOCK 58 www honeywell com ...
Page 69: ...6 PROTOCOL BLOCK 69 ...
Page 103: ...5 Click OK 6 PROTOCOL BLOCK 103 ...
Page 110: ...6 PROTOCOL BLOCK 110 www honeywell com ...
Page 183: ...PDC Details tab Figure 6 Detail Display of PDC Details tab 7 DEVICE SUPPORT BLOCK DSB 183 ...
Page 186: ...7 DEVICE SUPPORT BLOCK DSB 186 www honeywell com ...
Page 231: ...9 PROFIBUS I O MODULE PIOMB FUNCTION BLOCK 231 ...
Page 232: ...9 PROFIBUS I O MODULE PIOMB FUNCTION BLOCK 232 www honeywell com ...
Page 236: ...10 PROFIBUS GATEWAY MODULE PGM CONFIGURATION EXAMPLE 236 www honeywell com ...
Page 264: ...13 PROFIBUS GATEWAY MODULE PGM TROUBLESHOOTING 264 www honeywell com ...