Xenon/Granit User Guide
181
If the bar code has characters that the host application does not want included,
you can use the E4 command to replace those characters with something else. In
this example, you will replace the zeros in the bar code above with carriage returns.
Command string:
E402300DF10D
E4 is the “Replace characters” command
02 is the total count of characters to be replaced, plus the replacement characters
(0 is replaced by CR, so total characters = 2)
30 is the hex value for 0
0D is the hex value for a CR (the character that will replace the 0)
F1 is the “Send all characters” command
0D is the hex value for a CR
The data is output as:
1234
5678
ABC
<CR>
Stop replacing characters
E5
Terminates character replacement.
Syntax = E5.
Compare characters
FE
Compare the character in the current cursor position to the character “xx.” If
characters are equal, move the cursor forward one position.
Syntax = FExx
where xx
stands for the comparison character’s hex value for its ASCII code.
Refer to the
ASCII Conversion Chart (Code Page 1252),
decimal, hex and character codes.
Compare string
B2
Compare the string in the input message to the string “s.” If the strings are equal,
move the cursor forward past the end of the string. Syntax = B2nnnnS where nnnn
is the string length (up to 9999), and S consists of the ASCII hex value of each
character in the match string. For example, B2000454657374 will compare the
string at the current cursor position with the 4 character string “Test.”
Refer to the
ASCII Conversion Chart (Code Page 1252),
decimal, hex and character codes.
Check for a number
EC
Check to make sure there is an ASCII number at the current cursor position. The
format is aborted if the character is not numeric.
Summary of Contents for Granit 1910i
Page 20: ...xviii Xenon Granit User Guide ...
Page 36: ...16 Xenon Granit User Guide ...
Page 93: ...Xenon Granit User Guide 73 0 1 2 3 4 5 6 7 8 9 Save ...
Page 168: ...148 Xenon Granit User Guide Vertical Bottom to Top Upside Down Vertical Top to Bottom ...
Page 176: ...156 Xenon Granit User Guide ...
Page 179: ...Xenon Granit User Guide 159 Low Contrast Data Matrix Enhancements Off ...
Page 180: ...160 Xenon Granit User Guide ...
Page 286: ...266 Xenon Granit User Guide ...
Page 324: ...304 Xenon Granit User Guide ...
Page 349: ...Xenon Granit User Guide 329 CCB02 100BT CCB05 100BT Base Compliance Label locations ...
Page 350: ...330 Xenon Granit User Guide ...
Page 358: ...338 Xenon Granit User Guide ...
Page 370: ...350 Xenon Granit User Guide ...
Page 373: ...Xenon Granit User Guide 353 PROGRAMMING CHART 0 1 2 3 4 5 6 7 8 9 ...
Page 375: ......
Page 376: ... Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com Xenon UG Rev V 7 18 ...