Xenon/Granit User Guide
183
Insert a delay
EF
Inserts a delay of up to 49,995 milliseconds (in multiples of 5), starting from the
current cursor position. Syntax = EFnnnn where nnnn stands for the delay in 5ms
increments, up to 9999. This command can only be used with keyboard emulation.
Discard Data
B8
Discards types of data. For example, you may want to discard Code 128 bar codes
that begin with the letter A. In step 4 (
), select 6A (for Code 128), and in step
5, select 9999 (for all lengths). Enter FE41B8 to compare and discard Code 128 bar
codes that begin with the letter A.
Syntax = B8.
Note:
The B8 command must be entered after all other commands.
The Data Format must be
Required
) in order for the B8 command to
work.
If Data Format is On, but Not Required (
), bar code data that meets the B8
format is scanned and output as usual.
Because the data format needs to be
On
and
Required
(
) for the B8
command, you must input data formats for all bar codes you wish to discard as well
as all bar codes you wish to output.
Other data format settings impact the B8 command. If Data Format Non-Match Error
Tone is On (
), the scanner emits an error tone. If Data format Non-Match
Error Tone is Off, the code is disabled for reading and no tone is sounded.
Data Formatter
When Data Formatter is turned Off, the bar code data is output to the host as read,
including prefixes and suffixes.
You may wish to require the data to conform to a data format you have created and
saved. The following settings can be applied to your data format:
•
Data Formatter On, Not Required, Keep Prefix/Suffix
Scanned data is modified according to your data format, and prefixes and
suffixes are transmitted.
•
Data Formatter On, Not Required, Drop Prefix/Suffix
Scanned data is modified according to your data format. If a data format is
found for a particular symbol, those prefixes and suffixes are not transmitted. If
a data format is
not
found for that symbol, the prefixes and suffixes
are
transmitted.
•
Data Format Required, Keep Prefix/Suffix
Scanned data is modified according to your data format, and prefixes and
suffixes are transmitted. Any data that does not match your data format
Data Formatter Off
Summary of Contents for Granit 1910i
Page 20: ...xviii Xenon Granit User Guide ...
Page 36: ...16 Xenon Granit User Guide ...
Page 93: ...Xenon Granit User Guide 73 0 1 2 3 4 5 6 7 8 9 Save ...
Page 168: ...148 Xenon Granit User Guide Vertical Bottom to Top Upside Down Vertical Top to Bottom ...
Page 176: ...156 Xenon Granit User Guide ...
Page 179: ...Xenon Granit User Guide 159 Low Contrast Data Matrix Enhancements Off ...
Page 180: ...160 Xenon Granit User Guide ...
Page 286: ...266 Xenon Granit User Guide ...
Page 324: ...304 Xenon Granit User Guide ...
Page 349: ...Xenon Granit User Guide 329 CCB02 100BT CCB05 100BT Base Compliance Label locations ...
Page 350: ...330 Xenon Granit User Guide ...
Page 358: ...338 Xenon Granit User Guide ...
Page 370: ...350 Xenon Granit User Guide ...
Page 373: ...Xenon Granit User Guide 353 PROGRAMMING CHART 0 1 2 3 4 5 6 7 8 9 ...
Page 375: ......
Page 376: ... Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com Xenon UG Rev V 7 18 ...