GX-Series Control Panel Installation and Setup Guide
6-58
03 Intruder
The
Intruder
function is inactive when the system is unset (disarmed). When the system is set (armed),
activation of an
Intruder
zone causes a full alarm activation that requires to be reset with a code
authorized for
System Reset
– refer to option
51.6 = PARAMETERS.System Reset
and option
51.55.3 =
PARAMETERS.Confirm.Reduce Reset.
All zones are programmed as
Intruder
by default; this includes the zones on RIOs that are added to the
system at a later date.
04 24 Hours
The
24 Hours
zone function is continuously operational. In the unset (disarmed) state, activation of the zone
function generates a local alarm condition (the
Intruder
outputs are not activated). If the zone is activated
while the system is set, the
24 Hours
function operates the same as an
Intruder
function and results in a
full alarm condition. The
24 Hours
zone function requires a system reset following an activation in both the
set (armed) and unset (disarmed) conditions.
05 Security
The operation of the
Security
zone function is identical to the
24 Hours
zone function, except a
Security
zone activation in the unset (disarmed) state generates a local alarm (
Horn
outputs activated) that does not
require a system reset; any valid code (type 2 or above) cancels the alarm and resets the system. An
activation in the set (armed) state generates a full alarm that requires a system reset. The activation (
+
) and
restoration (–) of
Security
zones is recorded in the event log.
06 Dual (Double Knock) {Not for UL installations}
The operation of the
Dual
(Double Knock) function is identical to the
Intruder
function, with the exception
that an alarm condition is activated only when there have been two activations from any
Dual
zones
(assigned to the same group) within a 20 minute period while the system is set.
07 Entry
This function initiates the unsetting (disarming) procedure in the same way as a
Final
zone. However,
during the setting (arming) routine an
Entry
zone operates as an
Exit
zone type. This function is normally
used in conjunction with a
Push Set
zone, which acts as the exit terminator for the setting (arming)
procedure.
Pressing the
*
key when programming an
Entry
zone doubles the entry time of the group.
Opening an
Entry
zone during the exit time is reported on the keypad as an open zone; the
Entry/Exit
Horns
bleep rapidly to indicate that the zone is open.
08 Push Set {Not for UL installations}
This zone function is used to terminate the setting (arming) routine. The system sets when the
Push Set
zone, usually a push button, is activated. The
Entry/Exit Horn
stops immediately the button is pressed;
the system sets after four seconds, allowing the doors to settle to the closed state. The
Push Set
zone
remains inactive until the next setting (arming) routine.
NOTE: The Push Set zone can be either 1k
Ω
going to 2k
Ω
or 2k
Ω
to 1k
Ω
- refer to Installation Manual (II1-
0033), System Architecture for wiring details. The first time that the Push Set is used to terminate the
setting/arming, the button will require to be pressed twice; the first press identifies the normal status of
the button to the system.
Activating a
Push Set
zone during the exit time is not reported on the keypad as an open zone; the
Entry/
Exit Horns
bleep rapidly to indicate that the zone is open.
NOTE: The termination feature of a Final zone can be extended to terminate the setting (arming) of multiple
groups by pressing the * key when assigning a group to the zone. Refer to the Star * Group Function.
Summary of Contents for GX-48
Page 2: ......
Page 6: ...GX Series Control Panel Installation and Setup Guide iv ...
Page 26: ...GX Series Control Panel Installation and Setup Guide 2 18 ...
Page 32: ...GX Series Control Panel Installation and Setup Guide 3 6 ...
Page 40: ...GX Series Control Panel Installation and Setup Guide 4 8 ...
Page 46: ...GX Series Control Panel Installation and Setup Guide 5 6 ...
Page 184: ...GX Series Control Panel Installation and Setup Guide A 4 ...
Page 194: ...GX Series Control Panel Installation and Setup Guide C 2 ...
Page 200: ...GX Series Control Panel Installation and Setup Guide D 6 ...
Page 204: ...GX Series Control Panel Installation and Setup Guide F 2 ...
Page 207: ......