GX-Series Control Panel Installation and Setup Guide
2-4
+12V
+12V
+12V
+12V
A2
GND
+12V
B2
A1
R
TS
CTS
RX
TX
GND
+12V
B1
A
B
A
B
1
2
0V
0V
0V
0V
0V
3
4
0V
RIO 0
RIO 1
5
6
7
8
1
2
3
4
5
6
7
8
BLUE
BLUE
BLA
CK
INPUT RA
TING
120V
A
C
, 60 Hz
1.0A MAX
CONNECT T
O
A DEDICA
TED
CIRCUIT
T
AMPER SWITCH
FOR EXAMPLE
ON EXTERNAL
SIREN
LOUND
SPEAKER
8-32
Ω
DET
AIL
DOOR AND REAR
T
AMPER
(CONNECT AS SHO
WN)
SEE DET
AIL
BELO
W
WHITE
2A
INCOMING
TELEPHONE
LINE
RS232
CONNECTION
T
O PC SERIAL
COM POR
T
RS485
LINE 2
(NO
TE 1)
RS485
LINE 1
(NO
TE 1)
PREMISES
TELEPHONE
+BA
T
-BA
T
MODEL 1451
TRANSFORMER
OFF WALL
T AMPER
LK2
BA TTER
Y
ST AR
TUP
LK4
LINE
PHONE
RT
S
CTS
RX
TX
P
ANEL TERMINALS
D
ATA
B
U
S
CONNECTION
FOR PERIPHERAL
MODULES
(MK7 KEYP
AD
T
OUCHCENTER,
RIO EXP
ANDER,
ETHERNET MODULE
(LINE 1 ONL
Y)
DOOR CONTR
OL
MODULE)
AL
TERNA
TE PHONE
LINE CONNECTION FOR
RJ11 CONNECT
ORS
MICR
O
PR
OCESSOR
LK5 RS485 LINE 1, 680
Ω
TERMINA
TION
(NO
TE 2)
1 K
Ω
1 K
Ω
1 K
Ω
1 K
Ω
LK3 RS485 LINE 2, 680
Ω
TERMINA
TION
(NO
TE 2)
RS232 POR
T SOCKET
FOR CABLE A234
ENGINEER SOCKET
(RS485 LINE 2)
TRIGGER HEAD
(SEE T
ABLE
1)
ENGINEER SOCKET
(RS485 LINE 1)
LED 1 (FOR
TELECOMS)
LED 2 (FOR
TELECOMS)
12
1
RIO
SWITCH
2
3
45
6
1
ON
78
N/C
N/C
N/0
PULL-UP (DIP) SWITCHES
SW 3
LOUD SPEAKER
HORN OUTPUT
V
OLUME CONTR
OL
GND
A
UX T
AMP
2
34
1
23
4
1
RIO 1
RIO 0
PO
WERED
DETECT
OR
RELA
Y
OUTPUT
16 ON-BO
ARD ZONES
0V
0V
ZONE WIRING
(FOR ALL ZONE P
AIRS)
(TYPICAL)
9-W
A
Y D-TYPE
CONNECT
OR
(FEMALE)
(SEE T
ABLE
2)
CONNECTION
OUTPUT ADDRESS
MAX.
OUTPUT
PIN
TRIGGER 2
0002
8
100 mA
TRIGGER 3
0003
7
100 mA
TRIGGER 4
0004
6
100 mA
TRIGGER 5
0005
5
100 mA
0V GND
N/A
12
N/A
NO
T USED
N/A
11
N/A
NO
T USED
N/A
10
N/A
TRIGGER 1
0001
9
100 mA
TRIGGER 6
0006
4
100 mA
NO
T USED
N/A
3
N/A
NO
T USED
N/A
2
N/A
+12V
N/A
100 mA
1
9W
-D
SIGNAL NAME
PIN 6
SHOR
T
T
O PIN 4
PIN 4
SHOR
T
T
O PIN 6
PIN 2
Tx
PIN 3
Rx
PIN 7
CTS
PIN 8
R
TS
PIN 5
GR
OUND
GX-SOC-V4
RS485 D
A
T
A B
US LINES MUST USE D
AISY CHAIN
WIRING BETWEEN MODULES
.
NO
TE 1:
ALARM
CONT
A
CT
ALARM
CONT
A
CT
T
ABLE 1 -
TRIGGER HEAD
‡
T
ABLE 2 - RS232 CONNECTIONS
LED (LED 1) ST
A
TE
INDICA
TION
Flashes in time with r
inging signal
Line Ringing
The on-board
T
elecom Module monitors the PSTN line
under nor
mal idle state conditions
. LED 1 indicates the
comm
unications status
.
Pulses as each digit is dialed
Nor
mal indication when
making a call
Flic
k
er
ing dur
ing alar
m monitor
ing,
Remote ser
vicing and SMS
P
oor Comm
unication
On dur
ing alar
m monitor
ing,
Remote Ser
vicing and SMS
Nor
mal Comm
unication
Flashing at end of alar
m call
F
ailed Comm
unication
Single pulse at end of call
Nor
mal Comm
unication
On - 01s
, Off- 0.9s
Nor
mal Comm
unication
LED Off
No DC supply
T
ABLE 3 - COMMUNICA
TION ST
A
TUS
LED ST
A
TE
INDICA
TION
LED 2 Flashes
Ether
net Module sending or receiving data
LED 2 OFF
No Comm
unication on RS232 line
LED 2 ON
Comm
unication betw
een Control P
anel and PC
LED 1 ON
Ether
net Module connected to Ether
net
T
ABLE 4 -
ETHERNET
COMMUNICA
TION
ST
A
TUS
TIP
RING
TIP
RING
GX SERIES
SUMMAR
Y OF CONNECTIONS
RS485 EXP
ANSION
MODULE ST
ANDOFF
SWITCHED 0V OUTPUTS
A
UX 3
12V PO
WERED LO
AD
. EG:
SIREN,
W
ARNING LAMP
, ELECTR
ONIC
LOCK, ETC
. FOR ALL SWITCHED
0V OUTPUTS
+12V
SPI
PR
OGRAM
HEADER
T
AMPER
SWITCH
(OPTIONAL)
W
ARNING:
T
O PREVENT RISK
OF SHOCK DISCONNECT
TELEPHONE LINES A
T
TELCO
J
A
CK BEFORE SER
VICING
THIS UNIT
.
AC
LI
D
TA
M
P
E
R
1
LI
D
TA
M
P
E
R
2
RS-485
EXP
ANSION
MODULE
GX-520
ONL
Y
BR
O
WN
GREY
GREEN
RED
JUMPER MUST BE INST
ALLED
DO NO
T PLA
CE JUMPER
O
VER 2 PINS
.
DEVELOPMENT PURPOSE ONL
Y
ALL CIRCUITS ARE
PO
WER LIMITED
EXCEPT
THE OUTPUT OF
1451 TRANSFORMER
AND THE
BA
TTER
Y
.
LID
T
AMPER
1
LID
T
AMPER
2
* TB1
* TB2
* TB3
* TB4
12V 7AH BA
TTER
Y
CAP
A
CITY IS
REQ
UIRED FOR
EMERGENCY
ST
ANDBY FOR A
T
LEAST 4 HOURS
FOR UL
INST
ALLA
TIONS
TW
O 12V 7AH BA
TTERIES
ARE REQ
UIRED
UL Applications:
Propr
ietar
y,
Commercial Centr
al Station,
Local Mercantile Burglar Alar
m,
Access Control Unit, Standard
Line Secur
ity
, Dual Line
T
ransmission via PSDN and
DA
C
T
NO
TE:
MAINT
AIN
1/4" SEP
ARA
TION
OF PO
WER LIMITED
AND NON-PO
WER
LIMITED CIRCUITS
IC:
573F-GXSERIES
NO
TE 5:
FOR UL INST
ALLA
TIONS
, 26A
WG CABLE (MINIMUM) IS REQ
UIRED FOR
TELECO
CONNECTIONS
.
NO
TE 4:
FOR MORE INFORMA
TION, REFER
T
O
THE FOLLO
WING DOCUMENTS:
Q
UICK INST
ALLA
TION INSTR
UCTIONS (P/N 800-05372 REV A)
INST
ALLA
TION INSTR
UCTIONS (P/N 800-05928 REV A)
NO
TE 3:
WIRING METHOD SHALL BE IN A
CCORD
ANCE
WITH
THE NA
TIONAL ELECTRICAL CODE
[ANSI/NFP
A70], LOCAL CODES
, AND
THE A
UTHORITIES HA
VING JURISDICTION.
NO
TE 2:
EA
CH END OF
THE RS485 D
A
T
A B
US MUST BE
TERMINA
TED
WITH A 680 OHM
RESIST
OR A
CR
OSS
THE A&B
WIRES
. IF
THE P
ANEL DOES NO
T FORM ONE END
OF
THE B
US
, REMO
VE
THE LINK
T
O DISABLE
THE 680 OHM RESIST
OR.
‡
NO
T EV
ALU
A
TED BY UL.
‡
* FOR
TB1 -
TB4:
USE
EOL RESIST
OR (1K
OHM)
P/N 300-02343 SUPPLIED
IN SAP0166 P
A
CKA
GE
FOR UL INST
ALLA
TIONS
.
(NO
TE 5)
MEMOR
Y
BA
CKUP
BA
TTER
Y
2XRS485
EXP
ANSION CARD
INTERF
A
CE
BA
CKUP LITHIUM
BA
TTERIES
ARE T
O
BE REPLA
CED BY
TRAINED SER
VICE
PERSONNEL ONL
Y
.
NO
TE:
MAXIMUM LO
AD
FOR LOUD SPEAKER IS
100 mA DC
WITH SPEAKER
IMPED
ANCE OF 8
Ω
ZONES 1-8 (RIO 0 LINE 1)
ZONES 1-8 (RIO 1 LINE 0
SWITCH 3-8 ON)
OR
ZONES 1-8 (RIO 1 LINE 1
SWITCH SW3-8 OFF)
** TB5
** TB6
Memor
y bac
kup batter
y replacement:
1.
Remo
v
e memor
y bac
kup
batter
y with a small flat
head scre
wdr
iv
er
.
2.
Replace with good batter
y.
3.
Reconnect mains supply
.
4.
Reconnect 12V batter
y.
* NO
TES:
FOR
TB1 -
TB4:
USE
EOL RESIST
OR (1K
OHM)
P/N 300-02343 SUPPLIED
IN SAP0166 P
A
CKA
GE FOR
UL INST
ALLA
TIONS;
T
O
T
AL MAXIMUM CURRENT
DRA
W FOR
THE +12V A
UX
OUTPUTS = 1A.
**NO
TE:
FOR
TB5 AND
TB6:
T
O
T
AL MAXIMUM CURRENT
DRA
W FOR
THE SWITCHED A
UX OUTPUTS = 400mA.
Figure 2-4. PCB Layout
Summary of Contents for GX-48
Page 2: ......
Page 6: ...GX Series Control Panel Installation and Setup Guide iv ...
Page 26: ...GX Series Control Panel Installation and Setup Guide 2 18 ...
Page 32: ...GX Series Control Panel Installation and Setup Guide 3 6 ...
Page 40: ...GX Series Control Panel Installation and Setup Guide 4 8 ...
Page 46: ...GX Series Control Panel Installation and Setup Guide 5 6 ...
Page 184: ...GX Series Control Panel Installation and Setup Guide A 4 ...
Page 194: ...GX Series Control Panel Installation and Setup Guide C 2 ...
Page 200: ...GX Series Control Panel Installation and Setup Guide D 6 ...
Page 204: ...GX Series Control Panel Installation and Setup Guide F 2 ...
Page 207: ......