GX-Series Control Panel Installation and Setup Guide
6-113
Option 62 – Full Test
The
Full Test
option allows two zones to be selected and tested under full set conditions. Activating the
selected zone results in a full alarm condition, including remote signaling. Constantly active zones
(
Security, 24 Hours
,
PA
,
Fire
) remain active throughout the
Full Test
; an activation generates the
appropriate local or full alarm depending on the zone.
On selecting the
Full Test
option, the address and function of the first zone on the system is displayed.
Move to the required zone by pressing the
A>
or
<B
keys or by entering the zone address. Press the
ent
key.
An option is then given to choose a second confirm zone. If you press the
A>
(YES) key, select a second
required zone by pressing the
ent
key. If you press the
<B
(NO) key, the system begins the full setting
(arming) procedure. Activating the zone results in a full alarm condition. To end the full test unset (disarm)
the system.
Summary of Contents for GX-48
Page 2: ......
Page 6: ...GX Series Control Panel Installation and Setup Guide iv ...
Page 26: ...GX Series Control Panel Installation and Setup Guide 2 18 ...
Page 32: ...GX Series Control Panel Installation and Setup Guide 3 6 ...
Page 40: ...GX Series Control Panel Installation and Setup Guide 4 8 ...
Page 46: ...GX Series Control Panel Installation and Setup Guide 5 6 ...
Page 184: ...GX Series Control Panel Installation and Setup Guide A 4 ...
Page 194: ...GX Series Control Panel Installation and Setup Guide C 2 ...
Page 200: ...GX Series Control Panel Installation and Setup Guide D 6 ...
Page 204: ...GX Series Control Panel Installation and Setup Guide F 2 ...
Page 207: ......