GX-Series Control Panel Installation and Setup Guide
6-123
Use the
A> or <B
key to select the required group (
A1–D8
). When the end of a block is reached, the next
block of eight groups is displayed; use keys
1–8
to assign the relevant group in the current block to the zone;
press the
ent
key to accept the selection.
Account Group Autosetting
The GX-Series allows Account Group autosetting (autoarming). This means that several groups can be
bound together into one account group and, instead of a sending a normal CA event, the panel sends a CL
event.
Refer to menu option
56.1.2.2.2 = Communications.Internal Telecoms.Format.SIA.Group
Settings.Account No.
There are five stages to programming the
Autoset
function:
1. Autoset Status
0 = Off
(default)
1 = On
2 = Monitor
- if selected, the setting (arming) and unsetting (disarming) of the group is monitored:
•
if not set (armed) manually before the
On
time, then the
Set Late
output is activated
•
if unset (disarmed) before the
Off
time, then the
Unset (disarmed) Early
output is activated.
2. Prewarning
1 = Period
0 – 50 minutes
(default 30 minutes):
2 = Audible
(this can be turned ON or OFF)
This option determines the warning period given to users prior to the system autosetting. Outputs
programmed as
Prewarning
activate during the prewarning period. The output normally emits a
constant tone, however if an extension is not possible, then a pulsed tone is emitted and prewarn
activates at the Autoset time. At the end of the prewarning period, the system begins the timed setting
(arming) procedure.
NOTE: Pressing the esc key at any time during the prewarning resets and restarts the prewarning countdown.
If more than one group is in the prewarning period, each group can be viewed by pressing * and > or *
and <.
3. Extension
0 – 400 minutes
(default 30 minutes):
An autoset
Extension
can be assigned to each group on the system - programmed with different values
per group. Entering a user code during the
Prewarning
delays the autosetting/arming by the period
assigned to the
Extension
.
NOTE: The Late Working option (refer to option 45 = TIMERS) authorizes an Extension in advance of the
Prewarning period.
Late Set
appears if the system is not set (armed) after prewarn time plus 300 seconds (longest possible
exit delay) An
Extension
cannot be granted once the timed setting (arming) procedure begins.
4. Force Set
0 = Off (default)
1 = On
As a factory preset, any zone that is open at the start of the setting (arming) procedure - except
Final
,
Exit
,
Entry
, or
Push Set
, (or
Secure Final
or
Part Final
when acting as a
Final
) - is omitted by the
autoset routine whether or not it is omittable. If one of the above listed zones is open and is non-
omittable, on expiry of the time programmed in the
Fail-to-Set
parameter the
Fail-to-Set
outputs are
activated along with a full alarm.
5. Weekly Schedule
This option assigns a programmed weekly schedule for each group when the selected group is automatically
switched
On
(Autoset) and
Off
(Autounset).
When the keyswitch is activated twice during the exit time of an autoset, the autoset is temporarily
cancelled for a few seconds, then it restarts the exit time causing the panel to reset.
Summary of Contents for GX-48
Page 2: ......
Page 6: ...GX Series Control Panel Installation and Setup Guide iv ...
Page 26: ...GX Series Control Panel Installation and Setup Guide 2 18 ...
Page 32: ...GX Series Control Panel Installation and Setup Guide 3 6 ...
Page 40: ...GX Series Control Panel Installation and Setup Guide 4 8 ...
Page 46: ...GX Series Control Panel Installation and Setup Guide 5 6 ...
Page 184: ...GX Series Control Panel Installation and Setup Guide A 4 ...
Page 194: ...GX Series Control Panel Installation and Setup Guide C 2 ...
Page 200: ...GX Series Control Panel Installation and Setup Guide D 6 ...
Page 204: ...GX Series Control Panel Installation and Setup Guide F 2 ...
Page 207: ......