GX-Series Control Panel Installation and Setup Guide
B-3
Ev
SIA Event
Log
Log Event
Ev Type
Contact
Description
Event Description
Trigger
ID
Event
PUSH SET
Push set zone tested
ZONE
NOT SENT
611
KEYSWITCH
Keyswitch zone tested
ZONE
NOT SENT
611
SEC FINAL
Secure final zone test.
ZONE
NOT SENT
611
PRT FINAL
Part final zone tested
ZONE
NOT SENT
611
PRT ENTRY
Part entry zone tested
ZONE
NOT SENT
611
PA
PA zone tested
ZONE
NOT SENT
611
PA SILENT
PA silent zone tested
ZONE
NOT SENT
611
PA DELAY
PA delay zone tested
ZONE
NOT SENT
611
PA DEL/SL
PA delay sil zone tested
ZONE
NOT SENT
611
LINK
Link zone tested
ZONE
NOT SENT
611
SPARE
Spare zone tested
ZONE
NOT SENT
611
TAMPER
Tamper zone tested
ZONE
NOT SENT
611
BELL TAMP
Bell tamper zone tested
ZONE
NOT SENT
611
BEAM PAIR
Beam pair zone tested
ZONE
NOT SENT
611
BATT LOW
Battery Low zone tested
ZONE
NOT SENT
611
LINE FAIL
Line fail zone tested
ZONE
NOT SENT
611
AC FAIL
AC fail zone tested
ZONE
NOT SENT
611
LOG
Log zone tested
ZONE
NOT SENT
611
RM ACCESS
Rem acc zone tested
ZONE
NOT SENT
611
VIDEO
Video zone tested
ZONE
NOT SENT
611
VIDEO EXT
Video exit zone tested
ZONE
NOT SENT
611
INT DELAY
Intrud delay zone tested
ZONE
NOT SENT
611
SEC DELAY
Security del zone tested
ZONE
NOT SENT
611
SET LOG
Set Log zone tested
ZONE
NOT SENT
611
CUSTOM A
Custom A zone tested
ZONE
NOT SENT
611
CUSTOM B
Custom B zone tested
ZONE
NOT SENT
611
EXITGUARD
Exitguard zone tested
ZONE
NOT SENT
611
MASK
Mask zone tested
ZONE
NOT SENT
611
URGENT
Urgent zone tested
ZONE
NOT SENT
611
PA UNSET
PA unset zone tested
ZONE
NOT SENT
611
KSW RESET
Ksw. reset zone tested
ZONE
NOT SENT
611
VIBRATION
Vibration zone tested
ZONE
NOT SENT
611
ATM-1
ATM-1 zone tested
ZONE
NOT SENT
611
ATM-2
ATM-2 zone tested
ZONE
NOT SENT
611
ATM-3
ATM-3 zone tested
ZONE
NOT SENT
611
ATM-4
ATM-4 zone tested
ZONE
NOT SENT
611
ALARM EXT
Alarm extend zone test.
ZONE
NOT SENT
611
SOAK TEST
Soak test zone act
ZONE
NOT SENT
611
C - Closing
CA
Closing Report
FULL SET
Automatic Set
EVENT
10.SETTING
401
CE
Closing Extend
EXTENSION
Auto arm exten. delay
USER
10.SETTING
464
PREWARN
Auto arm prewarn delay
MISC
NEVER TR
464
CG
Close Area
PART SET
Part set by user
USER
10.SETTING
441
KSW P/SET
Part set by user
KSSET
10.SETTING
442
CI
Fail to Set
FAIL SET
Fail to Set
EVENT
7. SET FAULT 454
CJ
Late to Set
LATE SET
Late to Set
EVENT
10.SETTING
454
CL
Closing Report
FULL SET
Full set
USER
10.SETTING
401
FULL SET
Set by keypad
EVENT
10.SETTING
401
KSW SET
Keyswitch set
ZONE
10.SETTING
409
CP
Auto. Closing
REARM
Rearm after alarm
EVENT
10.SETTING
463
CR
Recent Close
RECEN.SET
Previous alarm was
EVENT2.INTRUDER
459
within 5 mins of set
CT
Late to Open
TIMEOUT
Entry timeout
EVENT
10.SETTING
None
D - Access
DD
Acces Denied
Invalid Card
Card tag unknown
MOD.
17.MAXTAG
421
DF
Door Forced
DCM EVENT
Door contact broken
MOD.
4.SECURITY 423
DG
Acces Granted
LEGAL CD
Legal code entered
USER
16.LOG
462
LEGAL CD
ATM code entered
USER
16.LOG
462
Valid
Card tag accepted
USER
17.MAXTAG
422
DK
Access Lockout
ILL-CODE
Illegal code entry
USER
16.LOG
421
REJECT CARD
Illegal Card tag
USER
17.MAXTAG
421
FOB
REJECT
Illegal
Fob
ZONE
10.SETTING
421
Summary of Contents for GX-48
Page 2: ......
Page 6: ...GX Series Control Panel Installation and Setup Guide iv ...
Page 26: ...GX Series Control Panel Installation and Setup Guide 2 18 ...
Page 32: ...GX Series Control Panel Installation and Setup Guide 3 6 ...
Page 40: ...GX Series Control Panel Installation and Setup Guide 4 8 ...
Page 46: ...GX Series Control Panel Installation and Setup Guide 5 6 ...
Page 184: ...GX Series Control Panel Installation and Setup Guide A 4 ...
Page 194: ...GX Series Control Panel Installation and Setup Guide C 2 ...
Page 200: ...GX Series Control Panel Installation and Setup Guide D 6 ...
Page 204: ...GX Series Control Panel Installation and Setup Guide F 2 ...
Page 207: ......